English
Language : 

HYS72T64300HP-3S-A Datasheet, PDF (29/50 Pages) Qimonda AG – 240-Pin Registered DDR2 SDRAM Modules
Internet Data Sheet
HYS72T[64/128]3x0HP–[3S/3.7/5]–A
Registered DDR2 SDRAM Modules
3.3.3
ODT AC Electrical Characteristics
This chapter contains the ODT AC electrical characteristics tables.
Symbol Parameter / Condition
TABLE 18
ODT AC Characteristics and Operating Conditions for DDR2-667
Values
Unit
Note
Min.
Max.
tAOND
tAON
ODT turn-on delay
ODT turn-on
2
tAC.MIN
2
tAC.MAX + 0.7 ns
tCK
ns
1)
tAONPD
ODT turn-on (Power-Down Modes)
tAC.MIN + 2 ns 2 tCK + tAC.MAX + 1 ns
ns
tAOFD
tAOF
ODT turn-off delay
ODT turn-off
2.5
tAC.MIN
2.5
tAC.MAX + 0.6 ns
tCK
ns
2)
tAOFPD
ODT turn-off (Power-Down Modes)
tAC.MIN + 2 ns 2.5 tCK + tAC.MAX + 1 ns ns
tANPD
ODT to Power Down Mode Entry Latency
3
—
tCK
tAXPD
ODT Power Down Exit Latency
8
—
tCK
1) ODT turn on time min. is when the device leaves high impedance and ODT resistance begins to turn on. ODT turn on time max is when
the ODT resistance is fully on. Both are measure from tAOND.
2) ODT turn off time min. is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance.
Both are measured from tAOFD.
Symbol
TABLE 19
ODT AC Characteristics and Operating Conditions for DDR2-533 and DDR2-400
Parameter / Condition
Values
Unit
Note
Min.
Max.
tAOND
ODT turn-on delay
2
2
tCK
tAON
ODT turn-on
tAC.MIN
tAC.MAX + 1 ns
ns
1)
tAONPD
ODT turn-on (Power-Down Modes)
tAC.MIN + 2 ns 2 tCK + tAC.MAX + 1 ns
ns
tAOFD
tAOF
ODT turn-off delay
ODT turn-off
2.5
tAC.MIN
2.5
tAC.MAX + 0.6 ns
tCK
ns
2)
tAOFPD
ODT turn-off (Power-Down Modes)
tAC.MIN + 2 ns 2.5 tCK + tAC.MAX + 1 ns ns
tANPD
ODT to Power Down Mode Entry Latency
3
—
tCK
tAXPD
ODT Power Down Exit Latency
8
—
tCK
1) ODT turn on time min. is when the device leaves high impedance and ODT resistance begins to turn on. ODT turn on time max is when
the ODT resistance is fully on. Both are measure from tAOND.
2) ODT turn off time min. is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance.
Both are measured from tAOFD.
Rev. 1.22, 2007-06
30
07042006-834B-Z31V