English
Language : 

HYS72T64300HP-3S-A Datasheet, PDF (17/50 Pages) Qimonda AG – 240-Pin Registered DDR2 SDRAM Modules
Internet Data Sheet
HYS72T[64/128]3x0HP–[3S/3.7/5]–A
Registered DDR2 SDRAM Modules
3.3
AC Characteristics
This chapter describes the AC characteristics.
3.3.1
Speed Grades Definitions
This chapter contains the Speed Grade Definition tables.
Speed Grades Definitions
• Table 12 “Speed Grade Definition Speed Bins for DDR2–667D” on Page 18
• Table 13 “Speed Grade Definition Speed Bins for DDR2–533C” on Page 19
• Table 14 “Speed Grade Definition Speed Bins for DDR2-400B” on Page 19
Speed Grade
TABLE 12
Speed Grade Definition Speed Bins for DDR2–667D
DDR2–667D
Unit
Note
IFX Sort Name
–3S
CAS-RCD-RP latencies
5–5–5
tCK
Parameter
Symbol
Min.
Max.
—
Clock Frequency
@ CL = 3
tCK
5
8
ns
1)2)3)4)
@ CL = 4
tCK
3.75
8
ns
1)2)3)4)
@ CL = 5
tCK
3
8
ns
1)2)3)4)
Row Active Time
tRAS
45
70000
ns
1)2)3)4)5)
Row Cycle Time
tRC
60
—
ns
1)2)3)4)
RAS-CAS-Delay
tRCD
15
—
ns
1)2)3)4)
Row Precharge Time
tRP
15
—
ns
1)2)3)4)
1) Timings are guaranteed with CK/CK differential Slew Rate of 2.0 V/ns. For DQS signals timings are guaranteed with a differential Slew
Rate of 2.0 V/ns in differential strobe mode and a Slew Rate of 1 V/ns in single ended mode.Timings are further guaranteed for normal
OCD drive strength (EMRS(1) A1 = 0)
2) The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross. The DQS / DQS, RDQS / RDQS,
input reference level is the crosspoint when in differential strobe mode
3) Inputs are not recognized as valid until VREF stabilizes. During the period before VREF stabilizes, CKE = 0.2 x VDDQ is recognized as low.
4) The output timing reference voltage level is VTT.
5) tRAS.MAX is calculated from the maximum amount of time a DDR2 device can operate without a refresh command which is equal to 9 x tREFI.
Rev. 1.22, 2007-06
18
07042006-834B-Z31V