Table 6: Static characteristics…continued
Limits are valid for −40 °C ≤ Tmb ≤ +150 °C and typical values for Tmb = 25 °C unless otherwise specified.
Symbol Parameter
Conditions
Min Typ
∆VBG(UV) hysteresis
Overvoltage [9]
-
0.5
VBG(OV) high supply threshold voltage
[8] 40
45
∆VBG(OV) hysteresis
Overload protection [9]
-
1
IL(lim)
limiting load current
Short circuit load protection [9][10]
VBG ≥ 9 V; VBL = VBG; Figure 8
[10] 12
18
VBL(TO) battery load threshold voltage
VBG = 16 V; Figure 11
[11] 8
10
Overtemperature protection [9][10]
VBG = 35 V
15 20
Tj(TO)
threshold junction temperature
[12] 150 170
∆Tj(TO) hysteresis
Status [5][9]
-
10
VSG
status clamping voltage
IS = 100 µA
5.5 7
VSG
status low voltage
IS = 100 µA; Figure 7
Tmb = −40 °C
-
-
Tmb = 25 °C
-
0.7
IS
status leakage current
VSG = 5 V
Tmb = 150 °C
-
-
RS
external pull-up resistor
Tmb = 25 °C
VSG = 5 V
-
0.1
[13] -
47
Max
-
50
-
24
12
25
190
-
8.5
1
0.8
15
1
-
Unit
V
V
V
A
V
V
°C
°C
V
V
V
µA
µA
kΩ
[1] For a high-side switch, the load pin voltage goes negative with respect to ground during the turn-off of an inductive load.
[2] This is the current drawn from the supply when the input is LOW, and includes leakage current to the load.
[3] Defined as in ISO 10483-1. For comparison purposes only.
[4] The supply and input voltages for the RBLon tests are continuous. The specified pulse duration is tp = 300 µs, and refers only to the
applied load current.
[5] 9 V ≤ VBG ≤ 16 V
[6] 9 V ≤ VBG ≤ 35 V. A low current load can be detected in the on-state.
[7] Undervoltage sensor causes the device to switch off and reset.
[8] Overvoltage sensor causes the device to switch off to protect the load.
[9] See Table 3 “Truth table”
[10] 5.5 V ≤ VBG ≤ 35 V
[11] The battery to load threshold voltage for short circuit is approximately proportional to the battery supply voltage.
[12] After cooling below the reset temperature the switch will resume normal operation.
[13] The status output is an open drain transistor and requires an external pull-up circuit to indicate a logic HIGH
9397 750 09384
Product data
Rev. 02 — 06 June 2002
© Koninklijke Philips Electronics N.V. 2002. All rights reserved.