English
Language : 

CS1W-OD232 Datasheet, PDF (52/70 Pages) Omron Electronics LLC – Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
● Industrial Switching Hubs
Product name Appearance
Specifications
Functions
No. of Failure
pors detection
Accessories
Current
Consumption
(A)
Model
Standards
Industrial
Switching Hubs
3
Quality of Service (QoS):
EtherNet/IP control data priority
Failure detection:
5
Broadcast storm and LSI error detection
10/100BASE-TX, Auto-Negotiation
5
No
• Power supply
connector
No
• Power supply
Yes
connector
• Connector for
informing error
0.22
W4S1-03B
UC, CE
0.22
W4S1-05B
0.22
W4S1-05C CE
■ Controller Link Units
Unit
type
Product name
Specifications
Wired shielded
twisted-pair cable *1
CPU Rack
CS1W-BC
@@3 @@2
Mountable Racks
C200HX/
HG/HE
Expansion
I/O Rack
CS1
Expansion
Rack
CS1W-BI
@@3 @@2
CS1 Long-
distance
Expansion
Rack
No. of
SYSMAC unit
BUS
numbers
Slave allocated
Rack
Current
consumption
(A)
5 V 26 V
system system
Model
Standards
*4 *4
*4 *4
Yes Yes
No
Yes Yes
Yes
No
0.33 --- CS1W-CLK23
CS1
CPU
Bus
Unit
Controller Link Optical ring H-PCF
Unit
cable *2
Optical ring GI
cable *3
*4 *4
Yes Yes
No
*4 *4
Yes Yes
Yes
1 unit
No number’s 0.52
words
---
CS1W-CLK13
UC1, N, L,
CE
*4 *4
*4 *4
Yes Yes
No
Yes Yes
Yes
No
0.65 --- CS1W-CLK53
Controller
Link Support
Board
Wired shielded twisted-pair
cable *1
H-PCF optical model
GI optical model
• CD-ROM × 1 *5
• Installation Guide (W467) × 1
• Communications Connector × 1
• CD-ROM × 1 *5
• Installation Guide (W467) × 1
• Optical Fiber Cable Bracket × 1
• Power Supply Connector × 1
3G8F7-CLK23-E
---
3G8F7-CLK13-E CE
3G8F7-CLK53-E
● Controller Link Options
Product name
Specifications
Relay Terminal Block for
Wired Controller Link Unit
Use for Wired Controller Link Units (set of 5).
Controller Link Repeater
Unit
CS1W-RPT01
PWR
T/R1
T/R2
SW1
1
2
BAUD
RATE
SL1
TER SW
ON
TER SW
SL2
IDNCP2U4TV
Wire-to-Wire Model
Wire-to-Optical (H-PCF) Model *2
Wire-to-Optical (GI) Model *3
These products are not mounted to the
PLC. (They are installed individually on
DIN Rail or with screws.)
Model
CJ1W-TB101
CS1W-RPT01
CS1W-RPT02
CS1W-RPT03
Standards
---
UC1, CE
*1. Use the following special cable for shielded, twisted-pair cable.
• ESVC0.5 × 2C-13262 (Bando Electric Wire: Japanese Company)
• ESNC0.5 × 2C-99-087B (Nihon Electric Wire & Cable Corporation: Japanese Company)
• ESPC 1P × 0.5 mm2 (Nagaoka Electric Wire Co., Ltd.: Japanese Company)
• Li2Y-FCY2 × 0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
• 1 × 2 × AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
• #9207 (Belden: US Company)
*2. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with connector.
*3. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
*4. • Up to four Pre-Ver. 1.2 Controller Link Units (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be mounted to the CS1
CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.
• Up to eight Controller Link Units with unit version 1.2 or later (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be
mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.
*5. The CD-ROM contains the following software.
• Controller Link (PCI) Driver
• FinsGateway Version 2003 (PCI-CLK Edition)
• FinsGateway Version 3 (PCI-CLK Edition)
• Setup Diagnostic Utility
• C Library
40
Programmable Controllers SYSMAC CS1G/H