English
Language : 

CS1W-OD232 Datasheet, PDF (18/70 Pages) Omron Electronics LLC – Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
● When Using a C200HX/HG/HE Expansion I/O Rack
It is possible to connect to an existing C200HX/HG/HE Expansion I/O Rack.
CS1 CPU Rack, CS1 Expansion Racks, and C200HX/HG/HE Expansion I/O Racks
CPU Rack
CS1 Expansion
Backplane
CS1W-BI@@@
CS1 I/O Connecting Cable
CS1W-CN@@3
CS1 Expansion Rack
(See note.)
Power Supply Unit
C200HW-P@@@@(@)
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
12 m
CS1 to C200H I/O
Connecting Cable
CS1W-CN@@1
C200HX/HG/HE Expansion
I/O Rack
Power Supply Unit
C200HW-P@@@@(@)
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
C200H I/O
Connecting
Cable
C200H-CN@@1
C200HX/HG/HE Expansion
I/O Rack
Power Supply Unit
C200HW-P@@@@(@)
Note: Multiple CS1 Expansion Racks can be connected, but the total number of Expansion Racks
must not exceed the maximum of 7. In addition, the Racks must be connected in order, with
CS1 Expansion Racks connected before C200HX/HG/HE Expansion I/O Racks.
Expansion Racks Configuration
• CS1 Expansion Racks
Unit name
Required number of units
Expansion Backplane
(CS1W-BI@@@)
1
Power Supply Unit 1
Maximum Number of
Configuration Units
Varies by backplane model
• C200HX/HG/HE Expansion Racks
Unit name
C200HX/HG/HE
Expansion I/O
Backplane
(C200HW-BI@@@)
Power Supply Unit
Maximum Number of
Configuration Units
Required number of units
One required for each
Expansion Rack
One required for each
Expansion Rack
Varies by backplane model
• Cables
Cable name
Required number of cables
CS1 I/O Connecting
Cable
(CS1W-CN@@3)
Number of CS1 Expansion
Racks
CS1 to C200H I/O
Connecting Cable
1
(CS1W-CN@@1)
C200H I/O Connecting Number of C200HX/HG/HE
Cable
Expansion I/O Racks
(C200H-CN@@1)
minus 1
CS1 CPU Rack and C200HX/HG/HE Expansion I/O Racks
CPU Rack
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
CS1 to C200H I/O
Connecting Cable
CS1W-CN@@1
C200HX/HG/HE I/O
Expansion Rack
Power Supply Unit
C200HW-P@@@@(@)
C200HX/HG/HE 12 m
Expansion
I/O Backplane
C200HW-BI@@@
C200H I/O
Connecting Cable
C200H-CN@@1
C200HX/HG/HE I/O
Expansion Rack
Power Supply Unit
C200HW-P@@@@(@)
C200HX/HG/HE
Expansion
I/O Backplane
C200HW-BI@@@
C200H I/O
Connecting Cable
C200H-CN@@1
C200HX/HG/HE I/O
Expansion Rack
Power Supply Unit
C200HW-P@@@@(@)
Expansion Racks Configuration
• C200HX/HG/HE Expansion I/O Racks
Unit name
C200HX/HG/HE
Expansion I/O
Backplane
(C200HW-BI@@@)
Power Supply Unit
Maximum Number of
Configuration Units
Required number of units
One required for each
Expansion Rack
One required for each
Expansion Rack
Varies by backplane model
• Cables
Cable name
Required number of cables
CS1 to C200H I/O
Connecting Cable
1
(CS1W-CN@@1)
C200H I/O Connecting Number of C200HX/HG/HE
Cable
Expansion I/O Racks
(C200H-CN@@1)
minus 1
6
Programmable Controllers SYSMAC CS1G/H