DE1E3KX332MN5AA01 Datasheet, PDF (76/84 Pages) Murata Manufacturing Co., Ltd. – Safety Standard Certified Ceramic Capacitors/ High Voltage Ceramic Capacitors | |||
|
◁ |
12
!Note ⢠Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
⢠This catalog has only typical speciï¬cations. Therefore, please approve our product speciï¬cations or transact the approval sheet for product speciï¬cations before ordering.
C85E.pdf
Apr.7,2014
Type KJ Speciï¬cations and Test Methods
Continued from the preceding page.
No.
Item
High
19
Temperature
Exposure
(Storage)
Capacitance
Change
D.F.
I.R.
Appearance
Within ±20%
Specifications
Char.
B, E
Specifications
D.F.V5.0%
1000MΩ min.
No marked defect except color change of outer
coating.
20
Thermal
Shock
Capacitance
Change
D.F.
Char.
B
E
Char.
B, E
Capacitance Change
Within ±10%
Within ±20%
Specifications
D.F.V5.0%
I.R.
Appearance
3000MΩ min.
No marked defect
Capacitance
Change
21
Resistance to
Solvents
D.F.
Char.
B
E
Char.
B, E
Capacitance Change
Within ±10%
Within ±20%
Specifications
D.F.V5.0%
I.R.
Appearance
3000MΩ min.
No marked defect
22
Biased
Humidity
Capacitance
Change
D.F.
Char.
B
E
Char.
B, E
Capacitance Change
Within ±10%
Within ±15%
Specifications
D.F.V5.0%
I.R.
Appearance
3000MΩ min.
No marked defect
Capacitance
Change
Char.
B
E
Capacitance Change
Within ±10%
Within ±20%
D.F.
Char.
B, E
Specifications
D.F.V5.0%
23
Moisture
Resistance
I.R.
3000MΩ min.
Test Method
Set the capacitor for 1000±12 hrs. at 150±3°C.
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs.
Post-treatment:
Capacitor should be stored for 24±2 hrs. at room condition.*
The capacitor should be subjected to 300 cycles.
Step
1
2
Temperature (ºC)
-55+0/-3
125+3/-0
Time (min)
30
30
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs.
Post-treatment:
Capacitor should be stored for 24±2 hrs. at room condition.*
Per MIL-STD-202 Method 215
Solvent 1: 1 part (by volume) of isopropyl alcohol
3 parts (by volume) of mineral spirits
Solvent 2: Terpene defluxer
Solvent 3: 42 parts (by volume) of water
1 part (by volume) of propylene glycol
monomethyl ether
1 part (by volume) of monoethanolomine
Apply the rated voltage and DC1.3+0.2/-0V (add 6.8kΩ resistor)
at 85±3°C and 80 to 85% humidity for 1000±12 hrs.
Pre-treatment:
Capacitor should be stored at 125±3°C for 1hr., then placed
at room condition* for 24±2 hrs.
Post-treatment:
Capacitor should be stored for 24±2 hrs. at room condition.*
Apply 24 hrs. of heat (25 to 65°C) and humidity (80 to 98%)
treatment shown below, 10 consecutive times.
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs.
Post-treatment:
Capacitor should be stored for 24±2 hrs. at room condition.*
Humidity Humidity Humidity Humidity Humidity
°C
90-98% 80-98% 90-98% 80-98% 90-98%
70
65
60
55
50
45
40
35
30
25
20
+10
-2
°C
15
10
Initial measurement
5
0
-5
-10
One cycle 24 hours
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Hours
* "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa