DEH Series Speciï¬cations and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Test Method
Appearance
Capacitance
Change
No marked defect
Within ±10%
13
Soldering Effect
(On-Preheat)
Dielectric Strength
(Between Lead
Wires)
Per item 4.
14
Temperature
Cycle
Appearance
Capacitance
Change
D.F.
I.R.
No marked defect
Within ±10%
0.4% max.
1000MΩ min.
Dielectric Strength
(Between Lead
Wires)
Per item 4.
7
Appearance
15
Humidity (Under
Steady State)
Capacitance
Change
D.F.
No marked defect
Within ±10%
0.4% max.
I.R.
1000MΩ min.
First the capacitor should be
stored at 120+0/-5°C for
60+0/-5 sec.
Then, as in the figure, the lead
wires should be immersed in
solder of 260+0/-5°C up to 1.5 to
Thermal
Screen
Capacitor
1.5
to 2.0mm
Molten
Solder
2.0mm from the root of terminal
for 7.5+0/-1 sec.
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs. before initial measurements.
Post-treatment:
Capacitor should be stored for 24±2 hrs. at room condition.*
The capacitor should be subjected to 5 temperature cycles.
<Temperature Cycle>
Step Temperature (°C) Time (min)
1
-25±3
30
2
Room Temp.
3
3
125±3
30
4
Room Temp.
3
Cycle time: 5 cycles
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs. before initial measurements.
Post-treatment:
Capacitor should be stored for 24±2 hrs. at room condition.*
Set the capacitor for 500 +24/-0 hrs. at 40±2°C in 90 to 95%
relative humidity.
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs. before initial measurements.
Post-treatment:
Capacitor should be stored for 1 to 2 hrs. at room condition.*
16
Humidity
Loading
Appearance
Capacitance
Change
D.F.
I.R.
No marked defect
Within ±10%
0.6% max.
1000MΩ min.
Apply the rated voltage for 500+24/-0 hrs. at 40±2°C in 90 to
95% relative humidity. (Charge/Discharge currentV50mA)
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed at
room condition* for 24±2 hrs. before initial measurements.
Post-treatment:
Capacitor should be stored for 1 to 2 hrs. at room condition.*
17 Life
Appearance
Capacitance
Change
D.F.
I.R.
No marked defect
Within ±10%
0.4% max.
2000MΩ min.
Apply a DC voltage of 200% of the rated voltage (DC500V) or
DC voltage of 150% of the rated voltage (DC1 to 3.15kV) for
1000 +48/-0 hrs. at 125±2°C with a relative humidity of 50%
max.
(Charge/Discharge currentV50mA)
Pre-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs. before initial measurements.
Post-treatment:
Capacitor should be stored at 125±3°C for 1 hr., then placed
at room condition* for 24±2 hrs.
* "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa