10
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
C85E.pdf
Apr.7,2014
DEC Series Specifications and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Test Method
Appearance
Capacitance
Change
13
Soldering Effect
(On-Preheat)
Dielectric Strength
(Between Lead
Wires)
Appearance
Capacitance
Change
Q
D.F.
Temperature
I.R.
14 and Immersion
Cycle
Dielectric Strength
(Between Lead
Wires)
Appearance
15
Humidity (Under
Steady State)
Capacitance
Change
Q
D.F.
I.R.
Appearance
16
Humidity
Loading
Capacitance
Change
Q
17 Life
D.F.
I.R.
Appearance
Capacitance
Change
Q
D.F.
I.R.
No marked defect
Char. SL: Within ±2.5%
Char. B: Within ±5%
Char. E: Within ±15%
Per item 4.
No marked defect
Char. SL: Within ±3%
Char. B: Within ±10%
Char. E: Within ±20%
Char. SL: 275+5/2C*2min. (30pF under)
350 min. (30pF min.)
Char. B, E: 4.0% max.
2000MΩ min.
Per item 4.
No marked defect
Char. SL: Within ±5%
Char. B: Within ±10%
Char. E: Within ±20%
Char. SL: 275+5/2C*2min. (30pF under)
350 min. (30pF min.)
Char. B, E: 5.0% max.
1000MΩ min.
No marked defect
Char. SL: Within ±7.5%
Char. B: Within ±10%
Char. E: Within ±20%
Char. SL:
100+10/3C*2min. (30pF under)
200 min. (30pF min.)
Char. B, E: 5.0% max.
500MΩ min.
No marked defect
Char. SL: Within ±3%
Char. B: Within ±10%
Char. E: Within ±20%
Char. SL: 275+5/2C*2min. (30pF under)
350 min. (30pF min.)
Char. B, E: 4.0% max.
2000MΩ min.
First the capacitor should be
stored at 120+0/-5°C for
60+0/-5 sec.
Then, as in the figure, the lead
wires should be immersed in
solder of 260+0/-5°C up to 1.5 to
Thermal
Screen
Capacitor
1.5
to 2.0mm
Molten
Solder
2.0mm from the root of terminal
for 7.5+0/-1 sec.
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition*1 for 24±2 hrs.
before initial measurements. (Char. B, E)
Post-treatment: Capacitor should be stored for 1 to 2 hrs. at
room condition.*1 (Char. SL)
Post-treatment: Capacitor should be stored for 4 to 24 hrs. at
room condition.*1 (Char. B, E)
The capacitor should be subjected to 5 temperature cycles,
then consecutively to 2 immersion cycles.
<Temperature Cycle>
Step Temperature (°C) Time (min)
1
-25±3
30
2
Room Temp.
3
3
85±3
30
4
Room Temp.
3
Cycle time: 5 cycles
<Immersion Cycle>
Step Temperature (°C) Time (min) Immersion Water
1
65+5/-0
15
Clean water
2
0±3
15
Salt water
Cycle time: 2 cycles
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition*1 for 24±2 hrs.
before initial measurements. (Char. B, E)
Post-treatment: Capacitor should be stored for 4 to 24 hrs. at
room condition.*1
Set the capacitor for 500+24/-0 hrs. at 40±2°C in 90 to 95%
relative humidity.
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition*1 for 24±2 hrs.
before initial measurements. (Char. B, E)
Post-treatment: Capacitor should be stored for 1 to 2 hrs. at
room condition.*1
Apply the rated voltage for 500+24/-0 hrs. at 40±2°C in 90 to
95% relative humidity. (Charge/Discharge currentV50mA.)
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition*1 for 24±2 hrs.
before initial measurements. (Char. B, E)
Post-treatment: Capacitor should be stored for 1 to 2 hrs. at
room condition.*1 (Char. SL)
Post-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition*1 for 24±2 hrs.
(Char. B, E)
Apply a DC voltage of 150% of the rated voltage for
1000+48/-0 hrs. at 85±2°C with a relative humidity of 50% max.
(Charge/Discharge currentV50mA.)
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition*1 for 24±2 hrs.
before initial measurements. (Char. B, E)
Post-treatment: Capacitor should be stored for 1 to 2 hrs. at
room condition.*1 (Char. SL)
Post-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition*1 for 24±2 hrs.
(Char. B, E)
*1 "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
*2 "C" expresses nominal capacitance value (pF).