English
Language : 

DE1E3KX332MN5AA01 Datasheet, PDF (47/84 Pages) Murata Manufacturing Co., Ltd. – Safety Standard Certified Ceramic Capacitors/ High Voltage Ceramic Capacitors
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
C85E.pdf
Apr.7,2014
DEA Series Specifications and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Test Method
13
Soldering Effect
(On-Preheat)
Appearance
Capacitance
Change
Dielectric Strength
(Between Lead
Wires)
No marked defect
Within ±2.5%
Per item 4.
First the capacitor should be
stored at 120+0/-5°C for
60+0/-5 sec.
Then, as in the figure, the lead
wires should be immersed in
solder of 260+0/-5°C up to 1.5 to
2.0mm from the root of terminal
Thermal
Screen
Capacitor
1.5
to 2.0mm
Molten
Solder
for 7.5+0/-1 sec.
Post-treatment:
Capacitor should be stored for 1 to 2 hrs. at room condition.*1
14
Temperature
Cycle
Appearance
Capacitance
Change
Q
I.R.
Dielectric Strength
(Between Lead
Wires)
No marked defect
Within ±5%
275+5/2C*2min. (30pF under)
350 min. (30pF min.)
1000MΩ min.
Per item 4.
The capacitor should be subjected to 5 temperature cycles.
<Temperature Cycle>
Step Temperature (°C) Time (min)
1
-25±3
30
2
Room Temp.
3
3
125±3
30
4
Room Temp.
3
Post-treatment:
Cycle time: 5 cycles
Capacitor should be stored for 1 to 2 hrs. at room condition.*1
15
Humidity (Under
Steady State)
Appearance
Capacitance
Change
Q
I.R.
No marked defect
Within ±5%
275+5/2C*2min. (30pF under)
350 min. (30pF min.)
1000MΩ min.
Set the capacitor for 500+24/-0 hrs. at 40±2°C in 90 to 95%
relative humidity.
Post-treatment:
Capacitor should be stored for 1 to 2 hrs. at room condition.*1
16
Humidity
Loading
Appearance
Capacitance
Change
Q
I.R.
No marked defect
Within ±5%
275+5/2C*2min. (30pF under)
350 min. (30pF min.)
1000MΩ min.
Apply the rated voltage for 500+24/-0 hrs. at 40±2°C in 90 to
8
95% relative humidity.
(Charge/Discharge currentV50mA)
Post-treatment:
Capacitor should be stored for 1 to 2 hrs. at room condition.*1
17 Life
Appearance
Capacitance
Change
Q
I.R.
No marked defect
Within ±3%
275+5/2C*2min. (30pF under)
350 min. (30pF min.)
2000MΩ min.
Apply a DC voltage of 150% of the rated voltage for
1000+48/-0 hrs. at 125±2°C with a relative humidity of 50%
max. (Charge/Discharge currentV50mA)
Post-treatment:
Capacitor should be stored for 1 to 2 hrs. at room condition.*1
*1 "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
*2 "C" expresses nominal capacitance value (pF).