English
Language : 

DE1E3KX332MN5AA01 Datasheet, PDF (19/84 Pages) Murata Manufacturing Co., Ltd. – Safety Standard Certified Ceramic Capacitors/ High Voltage Ceramic Capacitors
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
C85E.pdf
Apr.7,2014
Type KY/KH/KX Specifications and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Appearance No marked defect
Capacitance
Change
Within ±20%
I.R.
3000MΩ min.
14 Life
Dielectric
Strength
Per Item 6
Robustness
15 of
Terminations
Tensile
Bending
Lead wire should not be cut off. Capacitor should
not be broken.
Test Method
Impulse Voltage
Each individual capacitor should be subjected to a 5kV (Type
KX: 8kV) impulses for three times. Then the capacitors are
applied to life test.
100 (%)
90
50
Front time (T1) =1.2μs=1.67T
Time to half-value (T2) =50μs
30
0
t
T
T1
T2
Apply a voltage from Table 4 for 1000 hrs. at 125+2/-0°C, and
relative humidity of 50% max.
<Table 4>
Applied Voltage
170% of Rated Voltage except that once each hour the
voltage is increased to AC1000V(r.m.s.) for 0.1 sec.
Post-treatment:
Capacitor should be stored for 1 to 2 hrs. at room condition.*2
As shown in the figure at right, fix the body
of the capacitor and apply a tensile weight
gradually to each lead wire in the radial
direction of the capacitor up to 10N and keep W
it for 10±1 sec.
Each lead wire should be subjected to 5N of weight and bent
90° at the point of egress, in one direction, then returned to its
original position and bent 90° in the opposite direction at the
rate of one bend in 2 to 3 sec.
The capacitor should be individually wrapped in at least one but
not more than two complete layers of cheesecloth. The
capacitor should be subjected to 20 discharges. The interval
between successive discharges should be 5 sec. The UAC
should be maintained for 2 min. after the last discharge.
S1
F L1
L2
R
C1 C2
C3 Cx
Ct
Ut
Tr S2 UAC L3
L4
16 Active Flammability
The cheesecloth should not be on fire.
Oscilloscope
C1,2 : 1μF±10%
C3 : 0.033μF±5% 10kV
L1 to 4 : 1.5mH±20% 16A Rod core choke
Ct : 3μF±5% 10kV
R
: 100Ω±2%
Cx : Capacitor under test UAC : UR±5%
F : Fuse, Rated 10A
UR : Rated Voltage
Ut
: Voltage applied to Ct
Ux
5kV
*2 "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
time
Continued on the following page.