DE1E3KX332MN5AA01 Datasheet, PDF (52/84 Pages) Murata Manufacturing Co., Ltd. – Safety Standard Certified Ceramic Capacitors/ High Voltage Ceramic Capacitors | |||
|
◁ |
!Note ⢠Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
⢠This catalog has only typical speciï¬cations. Therefore, please approve our product speciï¬cations or transact the approval sheet for product speciï¬cations before ordering.
C85E.pdf
Apr.7,2014
DEB Series Speciï¬cations and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Test Method
Appearance
Capacitance
Change
No marked defect
Char. B: Within ±5%
Char. E: Within ±15%
Char. F: Within ±20%
13
Soldering Effect
(On-Preheat)
Dielectric Strength
(Between Lead
Wires)
Per item 4.
First the capacitor should be
stored at 120+0/-5°C for
60+0/-5 sec.
Then, as in the figure, the lead
wires should be immersed in
solder of 260+0/-5°C up to 1.5 to
Thermal
Screen
Capacitor
1.5
to 2.0mm
Molten
Solder
2.0mm from the root of terminal
for 7.5+0/-1 sec.
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored for 4 to 24 hrs. at
room condition.*
Appearance
Capacitance
Change
D.F.
Temperature
I.R.
14 and Immersion
Cycle
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 4.0% max.
Char. F: 7.5% max.
2000MΩ min.
Dielectric Strength
(Between Lead
Wires)
Per item 4.
The capacitor should be subjected to 5 temperature cycles,
then consecutively to 2 immersion cycles.
<Temperature Cycle>
Step Temperature (°C) Time (min)
1
-25±3
30
2
Room Temp.
3
3
85±3
30
4
Room Temp.
3
Cycle time: 5 cycles
<Immersion Cycle>
Step Temperature (°C) Time (min) Immersion Water
1
65+5/-0
15
Clean water
2
0±3
15
Salt water
Cycle time : 2 cycles
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored for 4 to 24 hrs. at
room condition.*
Appearance
Capacitance
9
15
Humidity (Under
Steady State)
Change
D.F.
I.R.
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 5.0% max.
Char. F: 7.5% max.
1000MΩ min.
Set the capacitor for 500+24/-0 hrs. at 40±2°C in 90 to 95%
relative humidity.
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored for 1 to 2 hrs. at
room condition.*
16
Humidity
Loading
Appearance
Capacitance
Change
D.F.
I.R.
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 5.0% max.
Char. F: 7.5% max.
500MΩ min.
Apply the rated voltage for 500+24/-0 hrs. at 40±2°C in 90 to
95% relative humidity. (Charge/Discharge currentV50mA)
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
17 Life
Appearance
Capacitance
Change
D.F.
I.R.
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 4.0% max.
Char. F: 7.5% max.
2000MΩ min.
Apply a DC voltage of 150% of the rated voltage for
1000+48/-0 hrs. at 85±2°C with a relative humidity of 50% max.
(Charge/Discharge currentV50mA)
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
* "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
50
|
▷ |