English
Language : 

DRQ-12-50-L48 Datasheet, PDF (2/26 Pages) Murata Power Solutions Inc. – 600W Digital Fully Regulated Intermediate DC-DC Bus Converter
DRQ-12/50-L48 Series
600W Digital Fully Regulated
Intermediate DC-DC Bus Converter
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ ➁
Output
Root Model ➀
IOUT
VOUT (Amps, Power
(Volts) max.) (Watts)
R/N (mV
pk-pk)
Typ. Max.
Regulation
(mV, max.)
Line Load
DRQ-12/50-L48 12 50 600 150 200 100 120
Input
IIN full
VIN Nom. Range IIN no load
(Volts) (Volts) load (mA) (Amps)
48 44-60 150 13.02
Efficiency
Min. Typ.
95% 96%
Dimensions with heat sink
(inches)
(mm)
2.3 x 1.45 x 1.1 58.4 x 36.8 x 27.94
➀ Please refer to the part number structure for additional ordering information and options.
➁ All specifications are typical at nominal line voltage and full load, +25°C unless otherwise noted. See
detailed specifications. Output capacitors are 1 μF || 10 μF. These caps are necessary for our test equip-
ment and may not be needed for your application.
PART NUMBER STRUCTURE
DRQ - 12 / 50 - L48 N B S A Lx - C
Digital Regulated
Quarter-brick
Nominal Output Voltage
RoHS Hazardous Materials compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder), standard
Pin length option
Blank = Standard pin length 0.180 in. (4.6 mm)
L1 = 0.110 in. (2.79 mm)➀
L2 = 0.145 in. (3.68 mm)➁
Maximum Rated Output
Current in Amps
Input Voltage Range:
L48 = 44-60 Volts (48V nominal)
A = PMBus™ (ABC 16-pin pinout)
Blank = No PMBus™ (DOSA 5-pin pinout)
S = Load-Sharing option
On/Off Control Logic
N = Negative logic
P = Positive logic
Baseplate or Integrated Heat Sink (optional)
B = Baseplate installed
K = Integrated Heat Sink
➀ Special quantity order is required; samples available with standard pin length only.
➁ Some model number combinations may not be available. See website or contact your local Murata sales representative.
Complete Model Number Example: DRQ-12/50-L48NKL1-C
Negative On/Off logic, Integrated Heat Sink installed, 0.110˝ pin length, RoHS-6 compliance
www.murata-ps.com/support