TECHNICAL NOTES
Power Management Overview
The module includes a wide range of readable and configurable power
management features that are easy to implement with a minimum of external
components. Furthermore, the module includes protection features that
continuously protect the load from damage due to unexpected system faults.
The SMBALERT pin alerts the host if there is a fault in the module. The follow-
ing product parameters can continuously be monitored by a host: Vout, Iout,
Vin, Temperature, and Power Good. The module is distributed with a default
configuration suitable for a wide range operation in terms of Vin, Vout, and
load. All power management functions can be reconfigured using the PMBus
interface. The product provides a PMBus digital interface that enables the user
to configure many aspects of the device operation as well as monitor the input
and output parameters. Please contact our FAE for special configurations.
Soft-start Power Up
The default rise time of the ramp up is 20 ms. When starting by applying
input voltage the control circuit boot-up time adds an additional 10 ms delay.
The soft-start power up of the module can be reconfigured using the PMBus
interface.
Over Voltage Protection (OVP)
The module includes over voltage limiting circuitry for protection of the load.
The default OVP limit is 20% above the nominal output voltage. If the output
voltage surpasses the OVP limit, the module can respond in different ways.
The default response from an over voltage fault is to immediately shut down.
The device will continuously check for the presence of the fault condition,
and when the fault condition no longer exists the device will be re-enabled.
The OVP fault level and fault response can be reconfigured using the PMBus
interface.
Over Current Protection (OCP, Current limit)
The module includes current limiting circuitry for protection at continuous over
load. The default setting for the product is hicup mode. The current limit could
be configured by simply setting the IOUT_OC_FAULT_LIMIT to be greater than
the IOUT_OC_WARN_LIMIT. The maximum value that the current limit could be
set is 50A.
Power Good
The module provides Power Good (PG) flag in the Status Word register that
indicates the output voltage is within a specified tolerance of its target level
and no fault condition exists. The Power Good pin default logic is negative and
it can be configured by MFR_PGOOD_POLARITY.
DRQ-12/50-L48 Series
600W Digital Fully Regulated
Intermediate DC-DC Bus Converter
PMBus Interface
This module offers a PMBus digital interface that enables the user to configure
many characteristics of the device operation as well as to monitor the input
and output voltages, output current and device temperature. The module can
be used with any standard two-wire I2C or SMBus host device. In addition, the
module is compatible with PMBus version 1.2 and includes an SMBALERT line
to help alleviate bandwidth limitations related to continuous fault monitoring.
The module supports 100 kHz and 400 kHz bus clock frequency only.
Monitoring via PMBus
A system controller (host device) can monitor a wide variety of parameters
through the PMBus interface. The controller can monitor fault conditions by
monitoring the SMBALERT pin, which will be asserted when any number of
pre-configured fault or warning conditions occur. The system controller can
also continuously monitor any number of power conversion parameters includ-
ing but not limited to the following:
• Input voltage
• Output voltage
• Output current
• Module temperature
Software Tools for Design and Production
For these modules, Murata-PS provides software for configuring and monitor-
ing via the PMBus interface. For more information please contact your local
Murata-PS representative.
Click here for Application Note AN-63, Digital DC-DC Evaluation Board
User Guide.
Click here for Application Note AN-64, Murata Power Brick GUI User Guide.
www.murata-ps.com/support
MDC_DRQ-12/50-L48NK.B02 Page 16 of 26