English
Language : 

MT41J256M8 Datasheet, PDF (80/211 Pages) Micron Technology – MT41J512M4 – 64 Meg x 4 x 8 Banks
Table 56: Electrical Characteristics and AC Operating Conditions (Continued)
Notes 1–8 apply to the entire table
DDR3-800
DDR3-1066
DDR3-1333
DDR3-1600
Parameter
Symbol Min Max Min Max Min Max Min Max
Exit self refresh to commands not requiring a
tXS
locked DLL
MIN = greater of 5CK or tRFC + 10ns; MAX = n/a
Exit self refresh to commands requiring a
locked DLL
tXSDLL
MIN = tDLLK (MIN); MAX = n/a
Minimum CKE low pulse width for self re-
fresh entry to self refresh exit timing
tCKESR
MIN = tCKE (MIN) + CK; MAX = n/a
Valid clocks after self refresh entry or power- tCKSRE
down entry
MIN = greater of 5CK or 10ns; MAX = n/a
Valid clocks before self refresh exit,
power-down exit, or reset exit
tCKSRX
MIN = greater of 5CK or 10ns; MAX = n/a
Power-Down Timing
CKE MIN pulse width
tCKE (MIN) Greater of 3CK Greater of 3CK Greater of 3CK Greater of 3CK
or 7.5ns
or 5.625ns
or 5.625ns
or 5ns
Command pass disable delay
tCPDED
MIN = 1; MAX = n/a
Power-down entry to power-down exit tim-
tPD
ing
MIN = tCKE (MIN); MAX = 9 * tREFI
Begin power-down period prior to CKE
registered HIGH
tANPD
WL - 1CK
Power-down entry period: ODT either
synchronous or asynchronous
PDE
Greater of tANPD or tRFC - REFRESH command to CKE LOW time
Power-down exit period: ODT either
PDX
synchronous or asynchronous
tANPD + tXPDLL
Power-Down Entry Minimum Timing
ACTIVATE command to power-down entry tACTPDEN
MIN = 1
PRECHARGE/PRECHARGE ALL command to
power-down entry
tPRPDEN
MIN = 1
REFRESH command to power-down entry
tREFPDEN
MIN = 1
MRS command to power-down entry
tMRSPDEN
MIN = tMOD (MIN)
READ/READ with auto precharge command
to power-down entry
tRDPDEN
MIN = RL + 4 + 1
WRITE command to
power-down entry
BL8 (OTF, MRS)
BC4OTF
tWRPDEN
MIN = WL + 4 + tWR/tCK (AVG)
BC4MRS
tWRPDEN
MIN = WL + 2 + tWR/tCK (AVG)
Unit Notes
CK
CK
28
CK
CK
CK
CK
CK
CK
CK
CK
CK
CK
CK
CK
37
CK
CK
CK
CK