English
Language : 

MIC3002_10 Datasheet, PDF (58/65 Pages) Micrel Semiconductor – FOM Management IC with Internal Calibration
Micrel, Inc.
MIC3002
OEM Calibration 1 (LUT Index)
D[7]
read/write
Default Value
Serial Address
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
0000 0000b = 00h
A6h
D[2]
read/write
Byte Address
18 = 12h
The look-up table index is derived from the current temperature measurement as follows:
D[1]
read/write
D[0]
read/write
INDEX = TAVG / 2
where T (n) is the current average temperature. This register allows the current table index to be read by the host. The table
AVG
base address must be added to LUTINDX to form a complete table index in physical memory. A valid OEM password is
required for access to this register. Otherwise, reads are undefined.
OEM Configuration 3 (OEMCFG3)
D[7]
LUTSEL
read/write
D[6]
TXFPOL
read/write
D[5]
GPOD
read/write
D[4]
GPOM
read/write
D[3]
GPOC
read/write
D[2]
TXFIN
read/write
D[1]
LOSDIS
read/write
D[0]
INTCAL
read/write
Default Value
0000 1000b = 08h
Serial Address
Byte Address
A6h
19 = 13h
This register is non-volatile and will be maintained through power and reset cycles. A valid OEM password is required for
access to this register. GPOD and GPOC are ignored when GPOM = 0. TXFPOL is ignored if TXFIN = 0.
Bit
D[7]
LUTSEL
D[6]
TXFPOL
D[5]
GPOD
Function
RX power look-up table input
selection bit
TXFIN active polarity select; a fault
is indicated when TXFIN = TXFPOL
GPO output drive
D[4]
GPOM GPO/RSOUT mode select
D[3]
GPOC GPO output control
D[2]
TXFIN TXFIN mode select
D[1]
LOSDIS RXLOS comparator disable
D[0]
INTCAL Calibration mode select
Operation
1 = RX power;
0 = temperature; read/write; ignored if INTCAL = 0.
0 = active-low;
1 = active-high; read/write; ignored if TXFIN = 0.
0 = open drain;
1 = push-pull; read/write; ignored if GPOM = 0.
0 = RSOUT; 1 = GPO; read/write.
0 = low; 1 = high; read/write; ignored if GPOM = 0.
0 = SHDN; 1 = TXFIN; read/write.
0 = enabled; 1 = disabled; read/write.
0 = external calibration;
1 = internal calibration; read/write.
BIAS DAC Setting (APCDAC)
Current VBIAS Setting
D[7]
read only
Default Value
Serial Address
Byte Address
D[6]
read only
D[5]
read only
D[4]
read only
D[3]
read only
0000 0000b = 00h
A6h
20 = 14h
D[2]
read only
D[1]
read only
D[0]
read only
This register reflects (reads back) the value set in the APC register (APCSET0, APCSET1, or APCSET2 whichever is
selected). A valid OEM password is required for access to this register.
July 2007
58
M9999-073107-B
hbwhelp@micrel.com or (408) 955-1690