MIC3002_10 Datasheet, PDF (54/65 Pages) Micrel Semiconductor – FOM Management IC with Internal Calibration
Micrel, Inc.
MIC3002
OEM Configuration Register 2 (OEMCFG2)
D[7]
I2CADR[3]
read/write
Default Value
Serial Address
Byte Address
D[6]
I2CADR[2]
read/write
D[5]
I2CADR[1]
read/write
D[4]
I2CADR[0]
read/write
D[3]
read/write
D[2]
read/write
1010 xxxxb = xxh (slave address = 1010xxxb)
A6h
2 = 02h
D[1]
read/write
D[0]
read/write
CAUTION: Changes to I2CADR take effect immediately! Any accesses following a write to I2CADR must be to the newly
programmed serial bus address. A valid OEM password is required for access to this register. This register is non-volatile and
will be maintained through power and reset cycles.
D[7:4]
D[3:0]
Bit(s)
I2CADR[3:0]
Reserved
Function
Upper four MSBs of the serial bus
slave address; writes take effect
immediately.
Operation
Read/write; non-volatile.
Read/write; non-volatile.
APC Setpoint x (APCSETx)
Automatic power control setpoint (unsigned binary) used when APCSEL[1:0] = 00
D[7]
read/write
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
D[1]
read/write
D[0]
read/write
Default Value
0000 0000b = 00h
Serial Address
A6h
Bytes Address
APCSET0: 3 = 03h
APCSET1: 4 = 04h
APCSET2: 5 = 05h
When A.P.C. is on, i.e., the APCCAL bit in OEMCAL0 is set, the value in APCSETx is added to the signed value taken from the
A.P.C. look-up table and loaded into the VBIAS DAC. When A.P.C. is off, the value in APCSET is loaded directly into the
VBIAS DAC, bypassing the look-up table entirely. In either case, the VBIAS DAC setting is reported in the VBIAS register. The
APCCFG bits determine the DAC’s response to higher or lower numeric values. A valid OEM password is required for access
to this register. This register is non-volatile and will be maintained through power and reset cycles.
Modulation Setpoint x (MODSETx)
Nominal VMOD setpoint
D[7]
read/write
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
D[1]
read/write
D[0]
read/write
Default Value
0000 0000b = 00h
Serial Address
A6h
Byte Address
MODSET0: 6 = 06h
MODSET1: 30 = 1Eh
MODSET2: 31 = 1Fh
When A.P.C. is on, the value corresponding to the current temperature is taken from the MODLUT look-up table, added to
MODSET and loaded into the VMOD DAC. This register is non-volatile and will be maintained through power and reset cycles. A
valid OEM password is required for access to this register.