English
Language : 

MIC3002_10 Datasheet, PDF (47/65 Pages) Micrel Semiconductor – FOM Management IC with Internal Calibration
Micrel, Inc.
MIC3002
Received Optical Power
D[7]
read-only
Default Value
D[6]
read-only
Serial Address
Byte Address
D[5]
read-only
D[4]
read-only
D[3]
read-only
0000 0000b = 00h (0mW)(6)
A2h
MSB (RXOPh): 104 = 68h
LSB (RXOPl): 105 = 69h
D[2]
read-only
D[1]
read-only
D[0]
read-only
Each LSB of RXOPl represents 25.6µW and each LSB of RXOPl represents 0.1µW. RXOPh is to be used in conjunction with
RXOPl to yield a sixteen-bit value. The values in RXOPh:RXOPl are in an unsigned binary format. The value in this register is
uncalibrated. The host should process the results using the scale factor and offset provided. See the External Calibration
section.
D[7]
TXDIS
read-only
Default Value
Serial Address
Byte Address
D[6]
STXDIS
read/write
D[5]
reserved
Control and Status (CNTRL)
D[4]
RSEL
read/write
D[3]
SRSEL
read/write
D[2]
XFLT
read-only
0000 0000b = 00h
A2h
110 = 6Eh
D[1]
LOS
read-only
D[0]
POR
read-only
Bit(s)
D[7]
TXDIS
D[6]
STXDIS
D[5]
D[5]
D[4]
RSEL
D[3]
SREL
D[2]
TXFLT
D[1]
LOS
Function
Reflects the state of the TXDISABLE pin
Soft transmit disable
Reserved
Reflects the state of the RSEL pin
Soft rate select
Reflects the state of the TXFAULT pin
Loss of signal. Reflects the state of the LOS pin
D[0]
POR
MIC3002 power-on status
Notes:
6. RXOPh will contain measured data after one A/D conversion cycle.
Operation
1 = disabled, 0 = enabled, read only.
1 = disabled; 0 = enabled.
Reserved - always write as zero.
1 = high; 0 = low.
1 = high (2Gbps); 0 = low (1Gbps).
1 = high (fault); 0 = low (no fault).
1 = high (loss of signal); 0 = low (no loss
of signal).
0 = POR complete, analog data ready;
1 = POR in progress.
July 2007
47
M9999-073107-B
hbwhelp@micrel.com or (408) 955-1690