10. MLX90363 Timing Specification
10.1. Timing Specification for 5V Application Diagram
DC Operating Parameters at VDD = 5V and for TA as specified by the Temperature suffix (E, K)6.
Parameter
Symbol
Test Conditions
Min Typ Max
Main Clock Frequency
Ck
15.2
18.8
Frame Rate
FR Trigger Mode 1 (Trg. Mod. 1),
1000
Markers 0&2, SCI 2MHz
All other modes, markers and SCI
500
Frequencies
Watchdog time-out
Wd See Section 18
15.3 18.8 20
Power On to First SCI message tStartUp See Section 14.20
20
(Start-up Time)
SCI protocol: Slave-select rising- tShort
120
edge to falling-edge
SCI protocol: EEPROMWrite Time teewrite Trimmed oscillator
32
Diagnostic Loop Time
tDiag FR = 1000 s-1,Trg.Mod.1, Mark 0&2
40
FR = 500 s-1
20
FR = 200 s-1
10
Internal 1MHz signal
t1us Ck = 19MHz
1
MISO Rise Time
CL = 30pF, RL = 10 kΩ
35
60
MISO Fall Time
CL = 30pF, RL = 10 kΩ
35
60
Magnetic Flux Density Frequency
Sinewave Flux Density(7)
FR = 1000 s-1
4
FR = 500 s-1
8
FR = 100 s-1
18
FR = 1000 s-1(8)
28
FR = 500 s-1(8)
14
FR = 200 s-1(8)
5.6
Units
MHz
s-1
s-1
ms
ms
us
ms
ms
ms
ms
us
ns
ns
Hz
Hz
Hz
Hz
Hz
Hz
6 Please contact Melexis for Timing specification for “L” Temperature suffix
7 Sensitivity monitors enable (See section 18). Beyond that frequency, the Sensitivity monitor should be disabled.
8 Limitation linked to the Automatic Gain Control. Beyond that frequency, there is a reduced immunity to norm change (like
vibration). See also Section 19.4.
3901090363
Rev. 005
Page 9 of 57
Data Sheet
Jul/13