14.20. Start-up Sequence (Serial Communication)
The MLX90363 serial interface is enabled after the internal start-up initializations and start-up checks.
Note: The start-up sequence of the MLX90363 firmware is described at chapter 19.1.
The recommended SCI start-up sequences (Master â Slave) are depicted in the following message
sequence charts, and timing diagrams. It usually starts with a NOP SI message. Ready is the first SO
message.
For safety critical applications, Melexis recommends performing two extra checks prior to the request of
the first regular data: oscillator frequency check and a readback of the diagnostic details (ROM, RAM,
ADC Monitorâ¦)
Message Sequence Chart
Start-up Sequence (Basic Scenario)
Message Sequence Chart
Start-up Sequence (Safety Scenario)
Master
Slave1
Master
Slave1
NOP(Challenge) ( )
Ready (ï)
NOP ( )
Ready (ï)
GETx ( )
Challenge Echo (ï)
Loop
GETx ( )
Regular Packet (ï)
OscCounterStart ( )
Challenge Echo (ï)
OscCounterStop ( )
OscStartAck (ï)
DiagDetails ( )
OscCounter (ï)
Loop
GETx ( )
DiagDetails (ï)
GETx ( )
Regular Packet (ï)
Figure 20 â MSCs Start-up sequence examples (basic and safety critical scenario)
VDD
POR
SI
SO
SS
NOP GETx
Ready Challenge Echo
tPOR
tStartUp
Figure 21 â Start-up sequence, basic scenario, timing diagram
VDD
POR
SI
SO
SS
NOP OscStart
Ready Challenge Echo
OscStop DiagDetails
StartAck OscCounter
GETx
DiagDetails
tPOR
tStartUp
tOscCounter
Figure 22 â Start-up sequence, safety critical scenario, timing diagram
Notes:
⢠The timing tStartUp is specified at chapter Timing Specifications (Section 10)
⢠The slave answers with NTT in case the first SI message occurs prior the end of the initial checks.
⢠The NOP - Challenge Echo is meant to diagnose the SCI link.
3901090363
Rev. 005
Page 36 of 57
Data Sheet
Jul/13
|
▷ |