8. MLX90363 Electrical Specification
DC Operating Parameters at VDD = 5V (5V Application Diagram) or VDD = 3.3V (3V3 Application
Diagram) and for TA as specified by the Temperature suffix (E, K and L).
Parameter
Symbol
Test Conditions
Nominal Supply Voltage
VDD5 5V Application Diagram
Nominal Supply Voltage
VDD33 3V3 Application Diagram
Supply Current (4)
IDD
Standby Current
ISTANDBY
Supply Current at VDD MAX
IDDMAX VDD = 18V
POR Rising Level
POR LH Voltage referred to VDEC
POR Falling Level
POR HL Voltage referred to VDEC
POR Hysteresis
POR Hyst Voltage referred to VDEC
MISO Switch Off Rising Level MT8V LH VDD level for disabling MISO(5)
MISO Switch Off Falling Level MT8V HL VDD level for disabling MISO(5)
MISO Switch Off Hysteresis MT8V Hyst VDD level for disabling MISO(5)
Input High Voltage Level
VIH
Input Low Voltage Level
VIL
Input Hysteresis
VHYS
Input Capacitance
CIN Referred to GND
Output High Voltage Level
VOH Current Drive IOH = 0.5 mA
Output Low Voltage Level
VOL Current Drive IOH = 0.5 mA
Output High Short Circuit Current IshortH VOUT forced to 0V
Output Low Short Circuit Current IshortL VOUT forced to VDD
Min Typ Max
4.5
5
5.5
3.15 3.3
3.45
12.5 15.5
3.5
4.5
18
2.6 2.8
3.1
2.5 2.7
2.9
0.1
7.5
9.5
6
7.5
1
2
65%*VDD -
-
-
- 35%*VDD
20%*VDD
20
VDD-0.4
0.4
20
30
25
30
Units
V
V
mA
mA
mA
V
V
V
V
V
V
V
V
V
pF
V
V
mA
mA
9. MLX90363 Isolation Specification
Only valid for the package code GO i.e. dual die version.
Parameter
Isolation Resistance
Symbol
Test Conditions
Between 2 dies
Min Typ Max
4
Units
MΩ
4 For the dual version, the supply current is multiplied by 2
5 Above the MT8V threshold, no SPI communication is possible.
3901090363
Rev. 005
Page 8 of 57
Data Sheet