English
Language : 

MLX90363 Datasheet, PDF (11/57 Pages) Melexis Microelectronic Systems – Triaxis® Magnetometer IC With High Speed Serial Interface
MLX90363
Triaxis® Magnetometer IC
With High Speed Serial Interface
11. MLX90363 Accuracy Specification
DC Operating Parameters at VDD = 5V (5V Application Diagram) or VDD = 3.3V (3V3 Application
Diagram) and for TA as specified by the Temperature suffix (E, K and L).
Parameter
Symbol
Test Conditions
Min Typ Max Units
ADC Resolution on the raw
signals X, Y and Z
RADC
Serial Interface Resolution
RSI On the angle value
On the X,Y,Z values
Offset on the Raw Signals X, Y
X0, Y0, Z0 TA = 25°C
and Z
Mismatch on the Raw Signals
X, Y and Z
SMISMXY
SMISMXZ
SMISMYZ
TA = 25°C
Between X and Y
Between X and Z(11)
Between Y and Z(11)
Magnetic Angle
Phase Error
ORTHXY
ORTHXZ
ORTHYZ
TA = 25°C
Between X and Y
Between X and Z(12)
Between Y and Z(12)
14
bit
14
bit
12
bit
-30
+30 LSB14
-1
1
%
-30
+30
%
-30
+30
%
-0.3
0.3 Deg
-10
10
Deg
-10
10
Deg
Intrinsic Linearity Error(13)
TA = 25°C,
Le Magnetic Angle ∠XY
-1
Magnetic Angle ∠XZ, ∠YZ(14)
-20
Supply Dependency
5V Application Diagram
VDD = 4.5 … 5.5V
-0.1
3V3 Application Diagram
VDD = 3.20 … 3.40V
Temperature suffix E and K
20mT
-0.8
50mT
-0.4
Temperature suffix L
20mT
-1
50mT
-0.6
MLX90363 Accuracy Specification continues…
1
Deg
20
Deg
0.1 Deg
0.8 Deg
0.4 Deg
1
Deg
0.6 Deg
11 The Mismatch between X or Y and Z can be reduced through the calibration of the SMISM (or k) factor in the end application.
See section 17.3.2 for more information
12 The Magnetic Angle Phase error X or Y and Z can be reduced through the calibration of the ORTH_B1B2 factor in the end
application. See section 17.3.2 for more information
13 The Intrinsic Linearity Error is a consolidation of the IC errors (offset, sensitivity mismatch, phase error) taking into account an
ideal rotating field. Once associated to a practical magnetic construction and the associated mechanical and magnetic
tolerances, the output linearity error increases.
14 The Intrisic Linearity Error for Magnetic Angle ∠XZ, ∠YZ can be reduced through the programming of the SMISM (or k) factor
and ORTH_B1B2. By applying the correct compensation, a non linearity error of +/-1 deg can be reached. See section 17.3.2 for
more information
3901090363
Rev. 005
Page 11 of 57
Data Sheet
Jul/13