English
Language : 

MLX90363 Datasheet, PDF (15/57 Pages) Melexis Microelectronic Systems – Triaxis® Magnetometer IC With High Speed Serial Interface
MLX90363
Triaxis® Magnetometer IC
With High Speed Serial Interface
Parameter
Symbol
Test Conditions
Min Typ Max
Clock Period
tSCLK
EE_PINFILTER = 1
EE_PINFILTER = 2
EE_PINFILTER = 3
450 500
900 1000
1800 2000
Clock Low Level
tSCLK_HI EE_PINFILTER = 1
225
EE_PINFILTER = 2
450
EE_PINFILTER = 3
900
Clock High Level
tSCLK_LO EE_PINFILTER = 1
225
EE_PINFILTER = 2
450
EE_PINFILTER = 3
900
Clock to Data Delay
tMISO EE_PINFILTER = 1 , Cload = 30pF
210
EE_PINFILTER = 2 , Cload = 30pF
300
EE_PINFILTER = 3 , Cload = 30pF
510
Data Capture Setup Time
tMOSI
30
/SS FE to SCLK RE
t1
EE_PINFILTER = 1
225
EE_PINFILTER = 2
450
EE_PINFILTER = 3
900
/SS FE to MISO Low Impedance
t2
EE_PINFILTER = 1
EE_PINFILTER = 2
EE_PINFILTER = 3
90 120
180 210
370 420
SCLK FE to /SS RE
t3
225
/SS RE to MISO High Impedance t4
EE_PINFILTER = 1
EE_PINFILTER = 2
EE_PINFILTER = 3
90 120
180 210
370 420
Sync Pulse Duration
tSyncPulse EE_PINFILTER = 1
EE_PINFILTER = 2
EE_PINFILTER = 3
520
10000
610
10000
820
10000
Table 1 - Serial Interface Timing Specifications
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Melexis recommends using the multi-slave application diagram
as shown on the right.
The SCLK, MISO and MOSI wires interconnect the slaves with
the master. A slave is selected by its dedicated /SS input. A
slave MISO output is in high-impedance state when the slave is
not selected.
Slaves can be triggered synchronously by sending Sync pulses
on the different /SS. The pulses must not overlap to avoid
electrical short-circuits on the MISO bus.
3901090363
Rev. 005
Page 15 of 57
Data Sheet
Jul/13