MLX90364 Datasheet, PDF (25/36 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor Assembly
50000
Digital value
[16bits]
MLX90364
Triaxis® Position Sensor Assembly
No filtering
FIR1 [11]
FIR2 [1111]
40000
0
10
20 Time [samples] 30
40
50
Figure 8: Noise response of the different filter
15.7. Programmable Diagnostic Settings
15.7.1. DIAG mode
Defines the Output Stage mode in case of Diag.
DIAG
mode [2:0]
0
5
6
7
Type
Disable
Digital
Digital
Digital
Descriptions
Output HiZ
open drain NMOS
open drain PMOS
Push-Pull
Comments
Not recommended
15.7.2. DIAG Level
Determines the reporting level (diagnostic low, diagnostic high) during start-up (both analog and PWM
mode), or during a fault reporting (Only in Analog mode).
In PWM mode, the fault reporting level shall in principle be 0 when the leading edge is a rising edge,
(resp. 1 for a falling edge) in order to detect the first cycle after start-up. MLX recommends then
DIAG Level = PWMPOL.
15.7.3. Field Strength Diagnostic
(i) FIELDTHRESHLOW
Defines the field strength limit under which a fault is reported.
The run-time field strength estimation (FieldStrength) is compared to 28 * FIELDTHRESHLOW.
The sensitivity of FIELDTHRESHLOW is typically 1mT/LSB. By default it is programmed to 10mT
MLX90364
Rev 4.1
Page 25 of 36
Datasheet