English
Language : 

MLX90364 Datasheet, PDF (19/36 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor Assembly
MLX90364
Triaxis® Position Sensor Assembly
15.2. Output Transfer Characteristic
There are 2 different possibilities to define the transfer function (LNR):
• With 4 arbitrary points (defined on X and Y coordinates) and 5 slopes
• With 17 equidistant points for which only the Y coordinates are defined.
Parameter
CLOCKWISE
DP
LNR_A_X
LNR_B_X
LNR_C_X
LNR_D_X
LNR_A_Y
LNR_B_Y
LNR_C_Y
LNR_D_Y
LNR_S0
LNR_A_S
LNR_B_S
LNR_C_S
LNR_D_S
LNR_Y0
LNR_Y1
…
LNR_Y16
W
CLAMP_LOW
CLAMP_HIGH
LNR type
Both
Both
Only 4 pts
Value
0 CounterClockWise
1 ClockWise
0 … 359.9999
0 … 359.9999
Unit
LSB
deg
deg
Only 4 pts
Only 4 pts
Only 4 pts
Only 16 pts
Only 16 pts
Both
Both
0 … 100
-17 … 0 … 17
-17 … 0 … 17
-50 … + 150
65.5 … 360
0 … 100
0 … 100
%
%/deg
%/deg
%
Deg
%
%
15.2.1. Enable scaling Parameter (only for LNR type 4 pts)
This parameter enables to scale LNR_x_Y from -50% - 150% according to the following formula
(Scaled Out)%VDD = 2 x Out%VDD – 50%
15.2.2. CLOCKWISE Parameter
The CLOCKWISE parameter defines the magnet rotation direction.
• CCW is defined by the 1-2-3-4 pin order direction for the Dual Mold Package.
• CW is defined by the reverse direction: 4-3-2-1 pin order direction for the Dual Mold Package.
Refer to the drawing in the sensitive spot positioning sections (Section 20.5)
MLX90364
Rev 4.1
Page 19 of 36
Datasheet
19/11/2015