English
Language : 

MLX90364 Datasheet, PDF (14/36 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor Assembly
MLX90364
Triaxis® Position Sensor Assembly
Ratiometry Error (Analog output
only)
Filter 2, B1 or B2 > 20mT
4.5V ≤ VDD ≤ 5.5V
LT4V ≤ VDD ≤ MT7V
0.10 0.2
-0.05
+0.05
-0.1
+0.1
Deg
%VDD
%VDD
10.2. Extended Range #1 : 15 mT ≤ B < 20 mT
DC Operating Parameters at nominal supply voltage (unless otherwise specified) and for TA as specified
by the Temperature suffix L.
Parameter
Symbol
Test Conditions
Offset on Raw Signals X,Y,Z X0,Y0,Z0
Thermal Offset Drift #1
at the DSP input (excl. DAC and
output stage)
TA = 25 Deg.C.
TA from -40 to 125degC
TA from -40 to 150degC
Noise pk-pk
Filter 0
Min Typ Max
-120
+120
-120
+120
-180
+180
75
Units
bits
LSB15
LSB15
In case of the use of the MLX90364 in those extended ranges, Melexis recommends validating the
headroom of the internal diagnostic and if necessary to disable the diagnostic mode related to the
amplitude of the flux strength and/or amplification factor of the device.
10.3. Extended Range #2: 10 mT ≤ B < 15 mT
DC Operating Parameters at nominal supply voltage (unless otherwise specified) and for TA as specified
by the Temperature suffix L.
Parameter
Symbol
Test Conditions
Offset on Raw Signals X,Y,Z X0,Y0,Z0
Thermal Offset Drift #1
at the DSP input (excl. DAC and
output stage)
TA = 25 Deg.C.
TA from -40 to 125degC
TA from -40 to 150degC
Noise pk-pk
Filter 0
Min Typ Max Units
-180
+180
bits
-180
+180 LSB15
-270
+270
112
LSB15
In case of the use of the MLX90364 in those extended ranges, Melexis recommends to validate the
headroom of the internal diagnostic and if necessary to disable the diagnostic mode related to the
amplitude of the flux strength and/or amplification factor of the device.
MLX90364
Rev 4.1
Page 14 of 36
Datasheet
19/11/2015