English
Language : 

MLX90364 Datasheet, PDF (12/36 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor Assembly
MLX90364
Triaxis® Position Sensor Assembly
8. MLX90364 Timing Specification
DC Operating Parameters at nominal supply voltage (unless otherwise specified) and for TA as specified
by the Temperature suffix L.
Parameter
Symbol
Test Conditions
Main Clock Frequency
Ck All contributors included thermal
drfit
Main Clock Frequency Thermal
Drift
∆TCk
Refresh Rate
Step Response Time
Ts
Filter=0(8)
Filter=1
Filter=2
Watchdog
Twd
Phase Shift
PS Filter=0
Start-up Cycle
Tsu Analog OUT Slew-rate excluded
Analog OUT Slew-rate
Min Typ Max
12.6 13.3 14
± 3%
275 290 305
6579 896
876 1195
1095 1494
114.5 118 121.5
0.16
5
25
37
Units
MHz
CkNOM
µs
µs
ms
Deg/Hz
ms
V/ms
9. MLX90364 PWM Timing Specification
DC Operating Parameters at nominal supply voltage = VPU (unless otherwise specified) and for TA as
specified by the Temperature suffix L.
Parameter
Digital Output Rise Time
Symbol
Test Conditions
LOW SIDE DRIVER – Mode 5
RL = 1 kΩ PU
PUSH-PULL – Mode 7
RL = 1 kΩ PU
Min Typ Max Units
80
130
µs
27
50
µs
Digital Output Fall Time
LOW SIDE DRIVER – Mode 5
RL = 1 kΩ PU
PUSH-PULL – Mode 7
RL = 1 kΩ PU
Start-up Cycle
Tsu PWM OUT Slew-rate excluded
8 See section 15.6 for details concerning Filter parameter
9 This represents a theoretical average response time
MLX90364
Rev 4.1
Page 12 of 36
27
50
µs
27
50
µs
Datasheet
19/11/2015