English
Language : 

MLX90364 Datasheet, PDF (10/36 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor Assembly
MLX90364
Triaxis® Position Sensor Assembly
7. MLX90364 Electrical Specification
DC Operating Parameters at nominal supply voltage (unless otherwise specified) and for TA as specified
by the Temperature suffix L.
Parameter
Symbol
Test Conditions
Min Typ Max Units
Nominal Supply Voltage
VDD
4.5
5
5.5
V
Power saving Enabled, All modes
10(2)
Supply Current
Idd
For Outmode=1
Power saving Disabled, All modes
6
10(2)
12
mA
For Outmode=1
8
12
Supply Current (Pwm mode) (3)
Ipeak
Peak current in Pwm mode 7
30
40
mA
Isurge Current(4)
Isurge
20
mA
Power-On reset ( rising )
HPOR_LH Refer to internal voltage Vdig
2
2.25
2.5
V
Power-On reset Hysteresis HPOR_Hyst
50
200
mV
Start-up Level ( rising )
MT4V LH
3.8
4.0
4.2
V
Start-up Hysteresis
MT4V Hyst
50
200
mV
PTC Entry Level ( rising )
MT7V_LH
5.8
6.2
6.6
V
PTC Entry Level Hysteresis MT7V_Hyst
50
200
mV
Output Short Circuit Current
Output Load (Analog mode)
Output Load (Pwm mode)
Ishort
RL_ana
RL_pwm
Vout = 0 V
Vout = 5 V
Vout = 18 V (TA = 25°C)
Pull-down to Ground
Pull-up to 5V
Pull-down to Ground
Pull-up to 5V
15
mA
15
mA
18
mA
4.7(5)
10
∞
kΩ
4.7(5)
10
∞
kΩ
1
10
∞
kΩ
1
10
∞
kΩ
Analog Saturation Output Level
Vsat_lo
Vsat_hi
Pull-up load RL ≥ 10 kΩ to 5 V
Pull-up load RL ≥ 5 kΩ to 18V
Pull-down load RL ≥ 5 kΩ
Pull-down load RL ≥ 10 kΩ
0.5
2
95
97
97.5 98.5
2
3
%VDD
%VDD
Digital Saturation Level
Open drain Output
(RL_PWM to Vbat)
Pull-up load RL_PWM ≤ 1 kΩ to 5V
98
Vo_min
Pull-up load RL_PWM ≤ 1 kΩ to 18V
Pull-up load RL_PWM ≤ 5.6 kΩ to 5V
90
96
Pull-up load RL_PWM ≤ 5.6 kΩ to 18V
73
%Vbat
Active Diagnostic Output Level
Diag_lo
Pull-up load RL ≥ 10 kΩ to 5 V
Pull-up load RL ≥ 5 kΩ to 18V
0.5
2
2
3
%VDD
(Digital saturation output level)
Diag_hi
Pull-down load RL ≥ 5 kΩ
Pull-down load RL ≥ 10 kΩ
95
97
97.5 98.5
%VDD
2 To reach 10mA, the power saving optionshould be enabled. This option switches off and on internal blocks dynamically. It can
be disabled in case of extreme emission requirements or if an analog output is required with a resistor on either supply or output
line. .
3 This current is due to the charge of output capacitors in PWM push-pull mode.
4 The specified value is valid during early start-up time only; the current might dynamically exceed the specified value, shortly,
during the Start-up phase.
5 The minimum specified value is mandatory to reach passive diagnostic output levels. A minimum 1k load resistor can be used
otherwise.