English
Language : 

MLX90364 Datasheet, PDF (11/36 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor Assembly
MLX90364
Triaxis® Position Sensor Assembly
Passive Diagnostic Output
Level
(Broken Track Diagnostic) (6)
BVSSPD
BVSSPU
BVDDPD
Broken VSS &
Pull-down load RL ≥ 10 kΩ
Broken VSS &
Pull-up load RL ≥ 1kΩ
Broken VDD &
Pull-down load RL ≥ 1kΩ
97.5
99.5
100
0
%VDD
%VDD
0.5
%VDD
BVDDPU
Broken VDD & Pull-up load RL ≥
5kΩ
2
%VDD
Digital output Ron
Ron
Diag_Low
Diag_Hi
15
120
30
300
Ohm
Clamped Output Level
Clamp_lo Programmable
Clamp_hi Programmable
0
100
%VDD(7)
0
100
%VDD(7)
As an illustration of the previous table, the MLX90364 fits the typical classification of the output span
described on the Figure 3.
100 %
90 %
80 %
96 %
92 %
88 %
Diagnostic Band (High)
Clamping High
70 %
60 %
50 %
Linear Range
40 %
30 %
20 %
10 %
0%
12 %
8%
4%
Clamping Low
Diagnostic Band (Low)
Figure 3 Example of Output Span Classification for typical application.
6 For detailed information, see also section 16
7 Clamping levels need to be considered vs the saturation of the output stage (see Vsat_lo and Vsat_hi)
MLX90364
Rev 4.1
Page 11 of 36
Datasheet
19/11/2015