English
Language : 

MLX90364 Datasheet, PDF (18/36 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor Assembly
MLX90364
Triaxis® Position Sensor Assembly
CUSTOMERID2
Cust. id reference
203h (ADB)
204h (ADD)
16
CUSTOMERID3
Cust. id reference
Sense info 16
LNR_Yn
17pts – Y-coordinate point n (n = 2,1,2 …16)
N/A
16
DIAG Settings
16 Bit Diagnostics enablling
FDFFh
16
CRC_DISABLE
Enable EEPROM CRC check ( 3131h= disable)
0h
16
MEMLOCK (ADD version) Write-protects USER/MLX EEPROM param.
0h
2
15. Description of End-User Programmable Items
15.1. Output Mode
The MLX90364 output type is defined by the Output Mode parameter.
Output
mode[2:0]
0
1
5
6
7
Type
Disable
Analog
Digital
Digital
Digital
Descriptions
Output HiZ
Analog Rail-to-Rail
open drain NMOS
open drain PMOS
Push-Pull
Comments
Not recommended
Analog
PWM
PWM
PWM
15.1.1. Analog Output Mode
The Analog Output Mode is a rail-to-rail and ratiometric output with a push-pull output stage configuration
allows the use of a pull-up or pull-down resistor.
15.1.2. PWM Output Mode
If PWM output mode is selected, the output signal is a digital signal with Pulse Width Modulation (PWM).
The PWM polarity is selected by the PWMPOL parameter:
• PWMPOL = 1 for a low level at 100%
• PWMPOL = 0 for a high level at 100%
The PWM frequency is selected by the PWMT parameter. The following table provides typical code for
different target PWM frequency and for both low and high speed modes.
PWW F (Hz)
100
250
500
PWMT (LSB)
@13.3MHz
44333
17733
8866
PWM res. (us) PWM res. (%)
0.240
0.240
0.240
0.0024
0.006
0.012
PWM res. (bit)
15.0
14.0
13.0
Notes:
• A more accurate trimming can be performed to take into account initial tolerance of the main
clock.
• The PWM frequency is subjected to the same tolerances as the main clock (see ∆TCk).
MLX90364
Rev 4.1
Page 18 of 36
Datasheet
19/11/2015