MLX75030 Universal ActiveLight Sensor Interface
Datasheet
• Ix:
• amboutx:
• TCIref:
• Ox:
• αx, βx:
calculated input light value
16-bit ADC converted value of the ambient channel
temperature coefficient of the reference current (typ. Value = +375ppm/K)
offset of the measurement (digital value)
calibration values for channel x (see below)
During calibration at least 2 light levels (Ix1 and Ix2) have to be supplied to the target ambient channel (x) with its photodiode
at the same known temperature T. The closer these values are chosen to the range used in application, the more accurate
the final result will be. During the setting of these light levels, the output of ambient channel x: amboutx1 and amboutx2 are
measured. This results in 2 equations and 2 unknowns: αx and βx. Both unknowns can be calculated from following formulas:
α=
T
ln
I1
I2

ambout1 − ambout2
and
β
=
ln

I1
1


−
α

ambout1
T
− 215

(2)
Note that these 2 values automatically correct any gain error of the connected photodiode and used lens system.
REVISION 005 – DECEMBER 2013
3901075030