Ambient Light Channels (detectors C, D)
Parameter
Symbol
Input current range for
detectors C
Iambc
Input current range for
detectors D
Iambd
input current threshold level Iambc_detect
Cinput current threshold level Iambd_detect
DInput capacity on ambient Cambc
PInDpCut capacity on ambient Cambd
PTrDaDnsfer function logarithmic Vamb
Output Ambient Channel C
Output Ambient Channel D
Slope Ambient Channel C
Slope Ambient Channel D
Ambient Channels Linearity
Error
Ambient light word length
Ambient light channel
resolution
Ambient light response time
Ambient PDC voltage
Ambient PDD voltage
Vambc
Vambd
Test Conditions Min
0.01
Typ Max
1040
0.0005
20
333
5.5
at 0.6V
1
at 0.6V
100
See section 8.3 and 8.4
At VCC=3,3V, Iin=100uA 29464
32768 36072
At VCC=3,3V, Iin=10uA 29464
32768 36072
At VCC=3,3V and 105°C 5300
5900 6500
At VCC=3,3V and 105°C 5300
5900 6500
for Iin ≥ Iambx_detect
including temperature
compensation
3
5
16
for averaging of 16
measurements
13
See section 7.1.3 for a
detailed explanation of
this parameter.
for Iin ≥ Iambx_detect
At VCC=3,3V, Iin=100uA 0.4
3
0.6 0.9
At VCC=3,3V, Iin=10uA 0.4
0.6 0.9
Error condition Err3
Units
uA
uA
nA
nA
nF
pF
LSB
LSB
LSB/dec
LSB/dec
%
bits
bits
ms
V
V
Note:
• Err3 is set if output voltage OUTN or OUTP of the ambient channel SC filter is out of range (meaning: <40% of VCCA
or >60% of VCCA). Critical error may occur after enabling of the referring Ambient Light Channel due to analog
settling time.
Table 6 : Ambient light channel specifications
REVISION 005 – DECEMBER 2013
3901075030