6. Sensor Specific Specifications
DC Operating Parameters TA = -40°C to 105°C, TA = 0°C to 70°C (C version), VDD = 3.0V to 3.6V
(unless otherwise specified)
ActiveLight Channels (Detectors A & B)
Parameter
Active light signal optical
transfer ratio
dc sunlight signal
Symbol
OTR = I LED
I PDAB
ISun
Test Conditions
fast full scale transition at Isunmax tsunrise
Min Typ Max Units
30
80000
140
900
uA
3.5
ms
min. relative active light
modulation
(referred to received IR signal)
∆I PDAB_ min
I PDAB
- 400Hz BW,
- max LED current of 1000mA
- 25°C
- dc sun constant
- ActiveLight response time
per channel 2.5ms
0.3
%
Carrier frequency range for
ActiveLight measurement
signal
Input capacitance PDA, PDB
f0
CPDA,B
selectable via “SetPF” 45.7
register, see also 7.4.6
At 1.0 V reverse bias
109.4 kHz
10
pF
DC light measurement range
DC light measurement offset
DC light measurement slope
DC light measurement
lDinCelaigrhittymereraosrurement word
lDeCnglitghht measurement
rTeIAsoTluetsitopnulse
Temperature coefficient of
TIA Test pulse
TIA Test pulse step width
Temperature coefficient of
TIA Test pulse step width
TIA Test pulse step width
variation
IDC range
IDC offset
IDC sens
At IDC = 0uA
Idc range: 0uA -> 275uA
for averaging of 8
ADCTIA_test_00
Tm=e2a7s°uCr,ements
DACA6=0, DACA7=0
Gain Anti-alias Filter=2
ADC Buffer bypassed
TC ADCTIA_test_00 DACA6=0, DACA7=0
Gain Anti-alias Filter=2
ADCTIA_test_step
ADC Buffer bypassed
T=27°C,
Gain Anti-alias Filter=2
ADC Buffer bypassed
TC ADCTIA_test_step Gain Anti-alias Filter=2
ADC Buffer bypassed
∆ ADC_TIA_TEST _ STEP Gain Anitalias Filter=2
ADC Buffer bypassed
0
4096 7168
115 150
5
16
13
35035 36182
275
10240
184
12
37570
uA
LSB
LSB/uA
%
Bit
Bit
LSB
-2.78
LSB/K
4458 5932 7770 LSB
-4.8
5
10
LSB/K
%
Error condition Err6
Critical error detected on TIA output, is TIA output outside 1.1V+/- (0.65 … 0.75V)
Note:
• Critical error may occur if the referring active light Channel is disabled and the according diagnostic function is
enabled (see EnChan register).
• Critical error may occur after enabling of the referring active light Channel due to analog settling time.
Table 4 : ActiveLight sensor channels specifications