English
Language : 

MAX14826 Datasheet, PDF (8/32 Pages) Maxim Integrated Products – IO-Link Device Transceiver
MAX14826
IO-Link Device Transceiver
AC Electrical Characteristics (continued)
(VCC = 18V to 36V, VL = 2.3V to 5.5V, VGND = 0V; all logic inputs at VL or GND; TA = -40°C to +105°C, unless otherwise noted.
Typical values are at VCC = 24V, VL = 3.3V, and TA = +25°C, unless otherwise noted.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
SPI TIMING (CS/PNP, SCLK/CQPP, SDI/DOPP, SDO/DOOC) (Figure 6)
SCLK/CQPP Clock Period
tCH+CL
SCLK/CQPP Pulse-Width High
tCH
SCLK/CQPP Pulse-Width Low
tCL
CS/PNP Fall to SCLK/CQPP Rise
Time
tCSS
MIN TYP MAX UNITS
83.3
ns
41.65
ns
41.65
ns
20
ns
SCLK/CQPP Rise to CS/PNP
Rise Hold Time
tCSH
20
ns
SDI/DOPP Hold Time
SDI/DOPP Setup Time
Output Data Propagation Delay
SDO/DOOC Rise and Fall Times
Minimum CS/PNP Pulse
tDH
tDS
tDO
tFT
tCSW
10
ns
10
ns
36
ns
20
ns
76.8
ns
Note 2: All devices are 100% production tested at TA = +25°C. Limits over the operating temperature range are guaranteed by
design.
Note 3: UV is an open-drain output. Connect UV to a voltage less than 5.5V through an external pullup resistor.
Note 4: Disable time measurements are load-dependent.
Note 5: RxFilter is on by default in parallel mode (SPI/PAR is low).
www.maximintegrated.com
Maxim Integrated │  8