English
Language : 

MAX1101 Datasheet, PDF (3/12 Pages) Maxim Integrated Products – Single-Chip, 8-Bit CCD Digitizer with Clamp and 6-Bit PGA
Single-Chip, 8-Bit CCD Digitizer
with Clamp and 6-Bit PGA
ELECTRICAL CHARACTERISTICS (continued)
(VDD = VREFBIAS = +4.75V to +5.25V, REFGND = 0V, REF- bypassed to REFGND with 0.1µF, CEXT = 47nF, TA = TMIN to TMAX,
unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
REFERENCE VOLTAGE INPUT
Positive Reference Voltage
VREF+ Internally generated, VREFBIAS = 5V
Negative Reference Voltage
VREF- Internally generated, VREFBIAS = 5V
POWER SUPPLIES
Positive Supply-Voltage Range
VDD
PSRR, PGA and ADC
PSRR 4.75V ≤ VDD ≤ 5.25V
Supply Current
IDD
DIGITAL INPUTS/OUTPUTS
Digital Input Voltage High
VIH
Digital Input Voltage Low
VIL
Digital Input Leakage Current
IIL
Digital Output Voltage High
VOH ISOURCE = 4mA
Digital Output Voltage Low
VOL
ISINK = 4mA
Digital Output Leakage Current
IOL
Output in high-impedance mode
DIGITAL TIMING SPECIFICATIONS (tr, tf ≤ 10ns, CL ≤ 50pF, unless otherwise noted)
SCLK Frequency
fSCLK
SCLK Pulse Width
tSPW
VIDSAMP Pulse Width
tVS
VIDSAMP to CLAMP Separation
tVB
LOAD Pulse Width
tLD
VIDSAMP Fall to SCLK Rise Time
tVLS MODE = 1
VIDSAMP Fall to DATA
tVLD MODE = 1
VIDSAMP to Reset Separation
tVR
(Note 2)
Reset to CLAMP Separation
tRB
(Note 2)
SCLK Rise to DATA
tSD
DATA Set-Up Time
tDSU
DATA Hold Time
tDH
LOAD Fall to SCLK Rise Time
tLS
MODE = 0
SCLK Rise to LOAD Rise Time
tSL
MODE = 0
MODE Setup Time
tMSU Same as bus-relinquish time
CLAMP Pulse Width
tBS
CLAMP Fall to Video Update
tBC
(Note 1)
Digital Quiet Time (Note 3)
tQ
± around VIDSAMP falling edge
MIN TYP MAX UNITS
2.94 3.00 3.06
V
0.49 0.50 0.51
V
4.75
5
5.25
V
48
60
dB
20
40
mA
3.5
-10
VDD - 0.5
-10
V
1.5
V
10
µA
V
0.5
V
10
µA
10 MHz
50
ns
500
ns
50
ns
50
ns
50
ns
60
ns
50
ns
50
ns
60
ns
20
ns
20
ns
50
ns
50
ns
50
ns
300
ns
20
ns
20
ns
Note 1: Due to leakage in the PGA and ADC, operation at sample rates below 1ksps is not recommended, as
performance may degrade, particularly at high temperatures.
Note 2: Production test equipment settling time prohibits leakage measurements below 1nA.
Lab equipment has shown the MAX1101 switch input leakage below 1pA at TA = +25°C, and below 50pA at TA = +70°C.
Note 3: Not a test parameter. Recommended for optimal performance.
_______________________________________________________________________________________ 3