7. TROUBLESHOOTING
Figure 7 provides a troubleshooting chart which lists some abnormal conditions along with the probable cause
and remedy for the condition. If the condition cannot be isolated, refer to Paragraph 9.3 for information on
obtaining further evaluation and repair.
ABNORMAL CONDITION
PROBABLE CAUSE
REMEDY
Hand Actuated Systems
Power unit piston will not extend when
actuated.
Power unit not connected to main air supply. Connect power unit to main air supply.
Faulty hand switch assembly or foot switch Replace switch assembly.
assembly.
Loss of power.
Improper lubrication.
Check operation of lubricator in main air
supply. If dry air is being used, lubricate in
accordance with Section 6.
Power unit internal seals worn or damaged. Replace seals or, for information on
obtaining evaluation and repair, refer to
Paragraph 9.3.
Figure 7
8. OPTIONS AND ACCESSORIES
Options and accessories may be ordered through your Tyco Electronics Representative, or call
1--800--526--5142, or send a facsimile of your purchase order to 717--986--7605, or write to:
CUSTOMER SERVICE (38--35)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105--3608
9. REPLACEMENT AND REPAIR
DANGER To avoid personal injury, ALWAYS disconnect the tooling assembly from main air supply and electrical power source
before replacing any parts.
9.1. Replacement
Replacement parts and recommended spares are identified and listed in Figure 9 and 10. The recommended
spares should be stocked for immediate replacement. Order replacement parts through your Tyco Electronics
Representative, or call 1--800--526--5142, or send a facsimile of your purchase order to 717--986--7605, or write
to:
CUSTOMER SERVICE (38--35)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105--3608
NOTE
i
For replacement parts for crimping heads, adapters, and crimping dies, refer to the instruction sheets packaged with
the specific head, adapter, or dies.
9.2. Stop Ring Replacement Procedure
A. Removal
1. Disconnect the unit from the main air supply.
2. Remove the tool holder (and cam) from the air cylinder body. Remove the friction ring.
12 of 15
Tyco Electronics Corporation
Rev C