English
Language : 

409-10039 Datasheet, PDF (10/15 Pages) Tyco Electronics – Micro Pneumatic Tooling
“Micro” Pneumatic Tooling Assembly 1490567- 1
409- 10039
5. Slide power unit locking collar toward tool holder assembly until it butts against the stop ring on the
power unit piston. Then turn locking collar clockwise to engage threads on the bottom of the tool holder
assembly. Tighten locking collar to fully secure the tool holder.
NOTE
i
When tool holder is properly installed, the locking collar should be butted against the stop ring and threads of the tool
holder should not be visible. If not properly installed, check that correct combination of cam and tool holder assembly
was used and that they are aligned properly.
6. Rotate the tool holder assembly one full turn in each direction and note that the power unit locking
collar rotates with the holder.
DANGER To avoid personal injury, periodically check that locking collar is tightly securing the tool holder assembly.
4.4. Crimping Head or Adapter Installation
DANGER When the power unit is connected to the main air supply, the power unit piston will retract. To avoid personal injury,
keep hands and fingers away from front of power unit.
Installation and removal procedures are contained in the instruction sheet packaged with the appropriate
crimping head or adapter. Figure 3 shows installation of a typical crimping head onto a typical tool holder
assembly. After the appropriate crimping head or adapter has been installed, the power unit may be
reconnected to the main air supply.
5. OPERATION
The procedures contained in this section describes the required operating steps for actuating the power unit.
For information concerning wire preparation, terminal or splice placement in crimping head or adapter, and wire
insertion, refer to the instructions packaged with the specific crimping head or adapter being used.
DANGER To avoid personal injury, ALWAYS keep fingers clear of crimping area when operating the power unit. Never place
anything within the crimping area except terminals or splices.
After the terminal or splice and wire have been properly positioned in the crimping head or adapter, depress
and momentarily hold the hand switch until the power unit extends and the crimping head jaws or crimping dies
have fully bottomed. When the jaws or dies have fully bottomed, release the hand switch. The power unit
piston should retract and the crimped product may be removed.
6. MAINTENANCE AND INSPECTION
It is recommended that a maintenance and inspection program be performed periodically to ensure dependable
operation. Frequency of inspections should be adjusted to suit your requirements through experience.
Frequency of inspection depends on:
S the care, amount of use, and handling of the system
S the degree of operator skill
S the presence of abnormal amounts of dust and dirt
S your own established standards
6.1. Inspection and Cleaning
At a minimum, the power unit should be inspected and cleaned after every eight hours of operation. To perform
this servicing, proceed as follows:
10 of 15
Tyco Electronics Corporation
Rev C