English
Language : 

6000 Datasheet, PDF (36/41 Pages) List of Unclassifed Manufacturers – THE BREAD BOARDING MEDIUM FOR SURFACE MOUNT
36 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet
Performance Characteristics (Continued)
Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Continued)
Sine
Frequency range
0.1 Hz to 20 MHz
Amplitude flatness
± 0.5 dB (relative to 1 kHz)
Harmonic distortion
–40 dBc
Spurious (nonharmonics)
–40 dBc
Total harmonic distortion
1%
SNR (50 Ω load, 500 MHz BW)
40 dB (Vpp ≥ 0.1 V); 30 dB (Vpp < 0.1V)
Square wave/pulse
Frequency range
0.1 Hz to 10 MHz
Duty cycle
20 to 80%
Duty cycle resolution
Larger of 1% or 10 ns
Rise/fall time
19 ns (10 to 90%)
Overshoot
< 2%
Asymmetry (at 50% DC)
± 1% ± 5ns
Jitter (TIE RMS)
500 ps
Ramp/triangle wave Frequency range
0.1 Hz to 200 kHz
Linearity
1%
Variable symmetry
0 to 100%
Symmetry resolution
1%
Pulse
Frequency range
0.1 Hz to 10 MHz
Pulse width
20 ns minimum
Pulse with resolution
10 ns
Edge time
Fixed at 19 ns (not variable)
Overshoot
< 2%
Noise
Bandwidth
20 MHz typical
Sine cardinal (sinc)
Frequency range
0.1 Hz to 1.0 MHz
Exponential rise/fall Frequency range
0.1 Hz to 5.0 MHz
Cardiac
Frequency range
0.1 Hz to 200.0 kHz
Gaussian pulse
Frequency range
0.1 Hz to 5.0 MHz
Arbitrary
Waveform length
1 to 8,192 points
Amplitude resolution
10 bits (including sign bit) 1
Repetition rate
0.1 Hz to 12 MHz
Sample rate
100 MSa/s
Filter bandwidth
20 MHz
Frequency
Sine wave and ramp accuracy
130 ppm (frequency < 10 kHz)
50 ppm (frequency > 10 kHz)
Square wave and pulse accuracy
[50 + frequency/200] ppm (frequency < 25 kHz)
50 ppm (frequency ≥ 25 kHz)
Resolution
0.1 Hz or 4 digits, whichever is larger
1.  Full resolution is not available at output due to internal attenuator stepping.