IS80LV51 Datasheet, PDF (20/43 Pages) Integrated Silicon Solution, Inc – CMOS SINGLE CHIP LOW VOLTAGE 8-BIT MICROCONTROLLER
IS80LV51
IS80LV31
transmission is requested. Transmission commences at
S1P1 of the machine cycle following the next rollover in
the divide-by-16 counter. Thus, the bit times are
synchronized to the divide-by-16 counter, not to the "write
to SBUF" signal.
The transmission begins when SEND is activated, which
puts the start bit at TXD. One bit timer later, DATA is
activated, which enables the output bit of the transmit shift
register to TXD. The first shift pulse occurs one bit time
after that. The first shift clocks a 1 (the stop bit) into the
ninth bit position of the shift register. Thereafter, only 0s
are clocked in. Thus, as data bits shift out to the right, 0s
are clocked in from the left. When TB8 is at the output
position of the shift register, then the stop bit is just to the
left of TB8, and all positions to the left of that contain 0s.
This condition flags the TX Control unit to do one last shift,
then deactivate SEND and set TI. This occurs at the 11th
divide-by-16 rollover after "write to SBUF".
Reception is initiated by a 1-to-0 transition detected at
RXD. For this purpose, RXD is sampled at a rate of 16
times the established baud rate. When a transition is
detected, the divide-by-16 counter is immediately reset,
and 1FFH is written to the input shift register.
At the seventh, eighth, and ninth counter states of each bit
time, the bit detector samples the value of RXD. The value
accepted is the value that was seen in at least two of the
three samples. If the value accepted during the first bit
time is not 0, the receive circuits are reset and the unit
continues looking for another 1-to-0 transition. If the start
bit proves valid, it is shifted into the input shift register, and
reception of the rest of the frame proceeds.
As data bits come in from the right, Is shift out to the left.
When the start bit arrives at the leftmost position in the
shift register (which in Modes 2 and 3 is a 9-bit register),
it flags the RX Control block to do one last shift, load SBUF
and RB8, and set RI. The signal to load SBUF and RB8
and to set RI is generated if, and only if, the following
conditions are met at the time the final shift pulse is
generated:
1. RI = 0, and
2. Either SM2 = 0 or the received 9th data bit = 1
If either of these conditions is not met, the received frame
is irretrievably lost, and RI is not set. If both conditions are
met, the received ninth data bit goes into RB8, and the first
eight data bits go into SBUF. One bit time later, whether
the above conditions were met or not, the unit continues
looking for a 1-to-0 transition at the RXD input.
Note that the value of the received stop bit is irrelevant to
SBUF, RB8, or RI.
Table 8. Serial Port Setup
Mode
0
1
2
3
0
1
2
3
SCON
10H
50H
90H
D0H
NA
70H
B0H
F0H
ISSI ®
SM2Variation
Single Processor
Environment
(SM2 = 0)
Multiprocessor
Environment
(SM2 = 1)
20
Integrated Silicon Solution, Inc.
ADVANCE INFORMATION MC018-0A
10/01/98