English
Language : 

HC55120_06 Datasheet, PDF (6/36 Pages) Intersil Corporation – Low Power Universal SLIC Family
Electrical Specifications
TA = -40°C to 85°C, VCC = +5V ±5%, VBH = -48V, VBL = -24V, PTG = Open, RP1 = RP2 = 0Ω, ZT = 120kΩ, RLIM = 38.3kΩ, RD = 50kΩ, RDC_RAC = 20kΩ,
ROH = 40kΩ, CH = 0.1µF, CDC = 4.7µF, CRT/REV = 0.47µF, GND = 0V, RL = 600Ω. Unless Otherwise Specified. (•) Symbol used to indicate the test
applies to the part. (NA) symbol used to indicate the test does not apply to the part. (Continued)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
HC55120 HC55121 HC55130/1 HC55140/1 HC55142/3 HC55150/1
OFF-HOOK LONGITUDINAL BALANCE
MIN
MIN
MIN
MIN
MIN
MIN
Longitudinal to Metallic (Note 7)
Forward and Reverse
IEEE 455 - 1985, RLR, RLT = 368Ω
Normal Polarity:
Forward
Only
Forward
Only
0.2kHz < f < 1.0kHz, 0°C to 70°C
-
-
-
dB
53
NA
NA
NA
NA
55
1.0kHz < f < 3.4kHz, 0°C to 70°C
-
-
-
dB
53
NA
NA
NA
NA
55
0.2kHz < f < 1.0kHz, -40°C to 85°C
-
-
-
dB
NA
53
63
63
63
NA
1.0kHz < f < 3.4kHz, -40°C to 85°C
-
-
-
dB
NA
53
58
58
58
NA
Reverse Polarity 0.2kHz < f < 3.4kHz, -
-
-
dB
(Figure 4)
NA
53
NA
58
58
55
MIN
MIN
MIN
MIN
MIN
MIN
Longitudinal to Metallic (Note 7)
Forward and Reverse
RLR, RLT = 300Ω,
Normal Polarity:
Forward
Only
Forward
Only
0.2kHz < f < 1.0kHz, 0°C to 70°C
-
-
-
dB
53
NA
NA
NA
NA
55
1.0kHz < f < 3.4kHz, 0°C to 70°C
-
-
-
dB
53
NA
NA
NA
NA
55
0.2kHz < f < 1.0kHz, -40°C to 85°C
-
-
-
dB
NA
53
63
63
63
NA
1.0kHz < f < 3.4kHz, -40°C to 85°C
-
-
-
dB
NA
53
58
58
58
NA
Reverse Polarity 0.2kHz < f < 3.4kHz, -
-
-
dB
(Figure 4)
NA
53
NA
58
58
55
MIN
MIN
MIN
MIN
MIN
MIN
Longitudinal to 4-Wire (Note 9)
(Forward and Reverse)
Normal Polarity:
Forward
Only
Forward
Only
0.2kHz < f < 1.0kHz, 0°C to 70°C
-
-
-
dB
53
NA
NA
NA
NA
61
1.0kHz < f < 3.4kHz, 0°C to 70°C
-
-
-
dB
53
NA
NA
NA
NA
61
0.2kHz < f < 1.0kHz, -40°C to 85°C
-
-
-
dB
NA
53
63
63
63
NA
1.0kHz < f < 3.4kHz, -40°C to 85°C
-
-
-
dB
NA
53
58
58
58
NA
Reverse Polarity 0.2kHz < f < 3.4kHz, -
-
(Figure 4)
dB
NA
53
NA
58
58
61
Metallic to Longitudinal (Note 10) FCC Part 68, Para 68.310 (Note 8)
40
50
-
Forward and Reverse
0.2kHz < f < 3.4kHz, (Figure 5)
dB
Forward
Only
•
Forward
Only
•
•
•
4-Wire to Longitudinal (Note 11)
Forward and Reverse
0.2kHz < f < 3.4kHz, (Figure 5)
40
-
-
dB
Forward
Only
•
Forward
Only
•
•
•