X5001
VTRIP Programming Parameters
Parameter
Description
tVPS
tVPH
tPCS
tTSU
tTHD
tWC
tVPO
tRP
VP
VTRAN
Vta1
Vta2
VTRIP program enable voltage setup time
VTRIP program enable voltage hold time
VTRIP programming CS inactive time
VTRIP setup time
VTRIP hold (stable) time
VTRIP write cycle time
VTRIP program enable voltage Off time (between successive adjustments)
VTRIP program recovery period (between successive adjustments)
Programming voltage
VTRIP programmed voltage range
Initial VTRIP program voltage accuracy (VCC applied-VTRIP) (programmed at 25°C)
Subsequent VTRIP program voltage accuracy [(VCC applied-Vta1)-VTRIP.
Programmed at 25°C.]
Vtr
VTRIP program voltage repeatability (Successive program operations. Programmed at
25°C.)
Vtv
VTRIP program variation after programming (0-75°C). (programmed at 25°C)
VTRIP programming parameters are periodically sampled and are not 100% tested.
Min.
1
1
1
1
10
0
10
15
1.7
-0.1
-25
Max.
10
18
5.0
+0.4
+25
Unit
µs
µs
µs
µs
ms
ms
µs
ms
V
V
V
mV
-25 +25 mV
-25 +25 mV
16
FN8125.1
May 30, 2006