English
Language : 

XC2734X Datasheet, PDF (85/106 Pages) Infineon Technologies AG – 16/32-Bit Single-Chip Microcontroller with 32-Bit Performance
XC2734X
XC2000 Family / Value Line
Electrical Parameters
Table 25 System PLL Parameters
Parameter
Symbol
Min.
VCO output frequency
fVCO CC 48
−
96
−
Values
Typ. Max.
−
112
−
38
−
160
−
76
Unit Note /
Test Condition
MHz VCOSEL= 00b
;
VCOmode= con
trolled
MHz VCOSEL= 00b
;
VCOmode= fre
e running
MHz VCOSEL= 01b
;
VCOmode= con
trolled
MHz VCOSEL= 01b
;
VCOmode= fre
e running
4.7.2.2 Wakeup Clock
When wakeup operation is selected (SYSCON0.CLKSEL = 00B), the system clock is
derived from the low-frequency wakeup clock source:
fSYS = fWU.
In this mode, a basic functionality can be maintained without requiring an external clock
source and while minimizing the power consumption.
4.7.2.3 Selecting and Changing the Operating Frequency
When selecting a clock source and the clock generation method, the required
parameters must be carefully written to the respective bit fields, to avoid unintended
intermediate states.
Many applications change the frequency of the system clock (fSYS) during operation in
order to optimize system performance and power consumption. Changing the operating
frequency also changes the switching currents, which influences the power supply.
To ensure proper operation of the on-chip EVRs while they generate the core voltage,
the operating frequency shall only be changed in certain steps. This prevents overshoots
and undershoots of the supply voltage.
Data Sheet
85
V1.3, 2010-04