9.2.6 STATCON Register
STATCON_REG
STATCON Register
Reset Value: 1101 1xxxB
7
6
5
4
3
2
1
0
CONFIG2
CONFIG1
CONFIG0
DIACLR2
DIACLR1
STATUS2 STATUS1 STATUS0
Field
Bits
CONFIG2 7
CONFIG1 6
CONFIG0 5
DIACLR2 4
DIACLR1 3
STATUS2 2
STATUS1 1
STATUS0 0
Type
wr
wr
wr
wr
wr
r
r
r
Description
VDD threshold test mode
’1’: VDD monitoring in normal operation
’0’: VDD thresholds are changed according to CONFIG1
changes thresholds in VDD threshold test mode (CONFIG2=’0’)
’1’: increase lower threshold of VDD monitoring to test switch off path
’0’: decrease upper threshold of VDD monitoring to test switch off path
latch function for overvoltage at VDD
’1’: overvoltage at VDD latched
’0’: overvoltage at VDD not latched
’0’: clears diagnosis of OUT2
always returns ’1’ at read access
’0’: clears diagnosis of OUT1
always returns ’1’ at read access
returns level at ABE
’0’: under voltage at VDD
’1’: VDD voltage above lower limit
0’: over voltage at VDD
’1’: VDD voltage below upper limit
Data Sheet