English
Language : 

TLI5012BE1000_15 Datasheet, PDF (28/37 Pages) Infineon Technologies AG – GMR-Based Angle Sensor
TLI5012B E1000
Specification
Table 4-15 SSC open-drain timing specification
Parameter
Symbol
Values
Min. Typ. Max.
SSC baud rate
fSSC
2.0
CSQ setup time
tCSs
300
CSQ hold time
tCSh
400
CSQ off
tCSoff
600
SCK period
tSCKp
500
SCK high
tSCKh
190
SCK low
tSCKl
190
DATA setup time
tDATAs
25
DATA hold time
tDATAh
40
Write read delay
twr_delay
130
Update time
tCSupdate
1
SCK off
tSCKoff
170
1) Not subject to production test - verified by design/characterization
Unit Note / Test Condition
Mbit/s
ns
ns
ns
ns
ns
ns
ns
ns
ns
μs
ns
Pull-up Resistor = 1kΩ1)
1)
1)
SSC inactive time1)
1)
1)
1)
1)
1)
1)
See Figure 4-131)
1)
4.4.2.2 SSC Data Transfer
The SSC data transfer is word-aligned. The following transfer words are possible:
• Command Word (to access and change operating modes of the TLI5012B E1000)
• Data words (any data transferred in any direction)
• Safety Word (confirms the data transfer and provides status information)
twr _del ay
COMMAND
READ Data 1
READ Data 2
SAFETY-WORD
SSC-Master is driving DATA
SSC-Slave is driving DAT A
Figure 4-10 SSC data transfer (data-read example)
twr_delay
COMMAND WRITE Data 1
SAFETY-WORD
SSC-Master is driving DATA
SSC-Slave is driving DAT A
Figure 4-11 SSC data transfer (data-write example)
Data Sheet
28
Rev. 1.1, 2015-09