TLI5012B E1000
Specification
Table 4-2 Operating range (cont’d)and parameters
Parameter
Symbol
Values
Unit Note / Test Condition
Min. Typ. Max.
Power-on time4)
Fast Reset time5)
tPon
tRfast
5
7 ms VDD > VDDmin;
0.5 ms Fast reset is triggered by
disabling startup BIST
(S_BIST = 0), then enabling
chip reset (AS_RST = 1)
1) Directly blocked with 100-nF ceramic capacitor
2) Values refer to a homogeneous magnetic field (BXY) without vertical magnetic induction (BZ = 0mT).
3) See Figure 4-1
4) During “Power-on time,” write access is not permitted (except for the switch to External Clock which requires a readout as
a confirmation that external clock is selected)
5) Not subject to production test - verified by design/characterization
The field strength of a magnet can be selected within the colored area of Figure 4-1. By limitation of the junction
temperature, a higher magnetic field can be applied. In case of a maximum temperature TJ = 100°C, a magnet
with up to 60mT at TJ = 25°C is allowed.
It is also possible to widen the magnetic field range for higher temperatures. In that case, additional angle errors
have to be considered.
100
90
80
70
60
50
40
30
70
60
50
30
+0.1° angle error @ 25mT
65
54
44
26
-40
25
85 100 125
Temperature (°C)
Figure 4-1 Allowed magnetic field range as function of junction temperature.
Data Sheet
17
Rev. 1.1, 2015-09