English
Language : 

TLI5012BE1000_15 Datasheet, PDF (19/37 Pages) Infineon Technologies AG – GMR-Based Angle Sensor
TLI5012B E1000
Specification
Table 4-5 Electrical parameters for 4.5 V < VDD < 5.5 V
Parameter
Symbol
Values
Unit Note / Test Condition
Min. Typ. Max.
Input signal low-level
Input signal high level
Output signal low-level
VL5
VH5
VOL5
0.7 VDD
0.3 VDD V
V
1V
DATA; IQ = -25 mA (PAD_DRV=’0x’),
IQ = -5 mA (PAD_DRV=’10’), IQ = -0.4
mA (PAD_DRV=’11’)
Pull-up current1)
IPU
-10
-10
1V
-225 μA
-150 μA
IFA,B,C; IQ = -15 mA (PAD_DRV=’0x’),
IQ = -5 mA (PAD_DRV=’1x’)
CSQ
DATA
Pull-down current2)
IPD
10
225 μA SCK
10
150 μA IFA, IFB, IFC
1) Internal pull-ups on CSQ and DATA pin are always enabled.
2) Internal pull-downs on IFA, IFB and IFC are enabled during startup and in open-drain mode, internal pull-down on SCK is
always enabled.
Table 4-6 Electrical parameters for 3.0 V < VDD < 3.6 V
Parameter
Symbol
Values
Unit Note / Test Condition
Min. Typ. Max.
Input signal low-level
Input signal high level
Output signal low-level
VL3
VH3
VOL3
0.7 VDD
0.3 VDD V
V
0.9 V
DATA; IQ = -15 mA
(PAD_DRV=’0x’), IQ = -3 mA
(PAD_DRV=’10’), IQ = -0.24 mA
(PAD_DRV=’11’)
0.9 V
IFA,IFB; IQ = - 10 mA
(PAD_DRV=’0x’), IQ = -3 mA
(PAD_DRV=’1x’)
Pull-up current1)
IPU
-3
-3
-225 μA
-150 μA
CSQ
DATA
Pull-down current2)
IPD
3
3
225 μA
150 μA
SCK
IFA, IFB, IFC
1) Internal pull-ups on CSQ and DATA pin are always enabled.
2) Internal pull-downs on IFA, IFB and IFC are enabled during startup and in open-drain mode, internal pull-down on SCK is
always enabled.
Data Sheet
19
Rev. 1.1, 2015-09