English
Language : 

TLI5012BE1000_15 Datasheet, PDF (23/37 Pages) Infineon Technologies AG – GMR-Based Angle Sensor
TLI5012B E1000
Specification
Table 4-10 Signal processing
Parameter
Symbol
Filter update period
tupd
Angle delay time without
prediction2)
tadelSSC
tadelIIF
Angle delay time with prediction2) tadelSSC
Min.
Values
Unit
Typ. Max.
42.7
μs
85.3
μs
170.6
μs
85
95 μs
150
165 μs
275
300 μs
120
135 μs
180
200 μs
305
330 μs
45
50 μs
65
70 μs
105
115 μs
tadelIIF
75
90 µs
95
110 µs
135
150 µs
Angle noise (RMS)
NAngle
0.08
°
0.05
°
0.04
°
1) Not subject to production test - verified by design/characterization
2) Valid at constant rotation speed
Note / Test Condition
FIR_MD = 1 (default)1)
FIR_MD = 21)
FIR_MD = 31)
FIR_MD = 11)
FIR_MD = 21)
FIR_MD = 31)
FIR_MD = 11)
FIR_MD = 21)
FIR_MD = 31)
FIR_MD = 1; PREDICT =
11)
FIR_MD = 2; PREDICT =
11)
FIR_MD = 3; PREDICT = 1
1)
FIR_MD = 1; PREDICT =
11)
FIR_MD = 2; PREDICT =
11)
FIR_MD = 3; PREDICT = 1
1)
FIR_MD = 11)
FIR_MD = 21)(default)
FIR_MD = 31)
All delay times specified in Table 4-10 are valid for an ideal internal oscillator frequency of 24 MHz. For the exact
timing, the variation of the internal oscillator frequency has to be taken into account (see Chapter 4.3.6)
Data Sheet
23
Rev. 1.1, 2015-09