4.3.2 ESD Protection
TLI5012B E1000
Specification
Table 4-7 ESD protection
Parameter
Symbol
Values
Unit
Min.
Max.
ESD voltage
VHBM
±4.0 kV
VCDM
±0.5 kV
1) Human Body Model (HBM) according to ANSI/ESDA/JEDEC JS-001
2) Charged Device Model (CDM) according to JESD22-C101
Notes
1)
2)
4.3.3 GMR Parameters
All parameters apply over BXY = 30mT and TA = 25°C, unless otherwise specified.
Table 4-8 Basic GMR parameters
Parameter
Symbol
Values
Unit
Min. Typ. Max.
X, Y output range
X, Y amplitude2)
X, Y synchronicity3)
X, Y offset4)
X, Y orthogonality error
RGADC
AX, AY
k
OX, OY
ϕ
6000
3922
87.5
-2048
-11.25
9500
100
0
0
±23230 digits
15781 digits
20620 digits
112.49 %
+2047 digits
+11.24 °
X, Y amplitude without magnet X0, Y0
1) Not subject to production test - verified by design/characterization
2) See Figure 4-2
3) k = 100*(AX/AY)
4) OY=(YMAX + YMIN) / 2; OX = (XMAX + XMIN) / 2
+4096 digits
Note / Test Condition
Operating range1)
At ambient temperature
Operating range1)
Operating range1)
VY
0 0°
+A
90°
180°
-A
Offset
270°
360°
Angle
Figure 4-2 Offset and amplitude definition
Data Sheet
20
Rev. 1.1, 2015-09