English
Language : 

TLI5012BE1000_15 Datasheet, PDF (18/37 Pages) Infineon Technologies AG – GMR-Based Angle Sensor
4.3
Characteristics
TLI5012B E1000
Specification
4.3.1 Input/Output characteristics
The indicated parameters apply to the full operating range, unless otherwise specified. The typical values
correspond to a supply voltage VDD = 5.0 V and 25 °C, unless individually specified. All other values correspond
to -40 °C < TJ < 125°C.
Within the register MOD_3, the driver strength and the slope for push-pull communication can be varied depending
on the sensor output. The driver strength is specified in Table 4-3 and the slope fall and rise time in Table 4-4.
Table 4-3 Input voltage and output currents
Parameter
Symbol
Values
Unit Note / Test Condition
Min. Typ. Max.
Input voltage
VIN
-0.3
Output current (DATA-Pad)
IQ
Output current (IFA / IFB / IFC - IQ
Pad)
1) Max. current to GND over open-drain output
2) At VDD = 5 V
5.5 V
VDD+ 0.3 V
-25 mA
-5 mA
-0.4 mA
-15 mA
-5 mA
PAD_DRV =’0x’, sink current1)2)
PAD_DRV =’10’, sink current1)2)
PAD_DRV =’11’, sink current1)2)
PAD_DRV =’0x’, sink current1)2)
PAD_DRV =’1x’, sink current1)2)
Table 4-4 Driver strength characteristic
Parameter
Symbol
Output rise/fall time
tfall, trise
Min.
Values
Unit
Typ. Max.
8 ns
28 ns
45 ns
130 ns
15 ns
30 ns
1) Valid for push-pull output
2) Not subject to production test - verified by design/characterization
Note / Test Condition
DATA, 50 pF,
PAD_DRV=’00’1)2)
DATA, 50 pF,
PAD_DRV=’01’1)2)
DATA, 50 pF,
PAD_DRV=’10’1)2)
DATA, 50 pF,
PAD_DRV=’11’1)2)
IFA/IFB, 20 pF,
PAD_DRV=’0x’1)2)
IFA/IFB, 20 pF,
PAD_DRV=’1x’1)2)
Data Sheet
18
Rev. 1.1, 2015-09