English
Language : 

TLI5012BE1000_15 Datasheet, PDF (16/37 Pages) Infineon Technologies AG – GMR-Based Angle Sensor
4
Specification
TLI5012B E1000
Specification
4.1
Absolute Maximum Ratings
Table 4-1 Absolute maximum ratings
Parameter
Symbol
Voltage on VDD pin with respect to VDD
ground (VSS)
Voltage on any pin with respect to VIN
ground (VSS)
Junction temperature
TJ
Magnetic field induction
B
Storage temperature
TST
Values
Unit Note / Test Condition
Min. Typ. Max.
-0.5
6.5 V Max 40 h/Lifetime
-0.5
6.5 V
VDD + V
0.5
-40
125 °C
200 mT Max. 5 min @ TA = 25°C
150 mT Max. 5 h @ TA = 25°C
-40
125 °C Without magnetic field
Attention: Stresses above the max. values listed here may cause permanent damage to the device.
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability. Maximum ratings are absolute ratings; exceeding only one of these values may
cause irreversible damage to the device.
4.2
Operating Range
The following operating conditions must not be exceeded in order to ensure correct operation of the TLI5012B
E1000. All parameters specified in the following sections refer to these operating conditions, unless otherwise
noted. Table 4-2 is valid for -40°C < TJ < 125°C unless otherwise noted.
Table 4-2 Operating range and parameters
Parameter
Symbol
Min.
Supply voltage
VDD
3.0
Supply current
IDD
Magnetic induction at TJ =
BXY
30
25°C2)3)
30
30
Extended magnetic induction
BXY
25
range at TJ = 25°C2)3)
Angle range
Ang
0
POR level
POR hysteresis
VPOR
2.0
VPORhy
Values
Typ.
5.0
14
30
Unit Note / Test Condition
Max.
5.5 V 1)
16 mA
50 mT
60 mT
70 mT
30 mT
-40°C < TJ < 125°C
-40°C < TJ < 100°C
-40°C < TJ < 85°C
Additional angle error of 0.1°
360 °
2.9 V
mV
Power-on reset
Data Sheet
16
Rev. 1.1, 2015-09