Functional Description
D7 D6 D5 D4 D3 D2 D1 D0
FSL
Figure 14 Output Coder
Failure indicator bit
(only valid during NCS = LOW to the
first L to H CLK change )
1 = failure stored
0 = no failure
Status INJ4B
11 = no failure
10 = short circuit
01 = shortcircuit
Status INJ1B
Status INJ4A
Status INJ1A
Table 3 Failures Coding and Priorities
valid for i=0 or i=2 or i=4 or i=6
Failure
SC
OL
FSL
0
0
0
0
1
1
1
0
1
1
1
1
SPI Bits
Di+1
Di
1
1
0
1
1
0
1
0
The first bit of the shift register (FSL) is set to high level if there is a failure stored in the failure register.
Input Coder
t1 and t2 times are coded on 3 bit and 5 bit respectively as described hereafter: